Multi-scenarios of effective demand side management in Navanakorn industrial promotion zone

P. Teansri, B. Hongpeechar, Rittirong Intarajinda, P. Bhasaputra, W. Pattaraprakorn
{"title":"Multi-scenarios of effective demand side management in Navanakorn industrial promotion zone","authors":"P. Teansri, B. Hongpeechar, Rittirong Intarajinda, P. Bhasaputra, W. Pattaraprakorn","doi":"10.1109/ESD.2010.5598868","DOIUrl":null,"url":null,"abstract":"This paper studies the multi-scenarios of effective demand side management by implementing energy conservation programs in 51 designated factories according the Energy Conservation Promotion Act No. 2 B.E. 2550 (2007). In addition, 5% of peak demand reduction is estimated from the industries in Navanakorn industrial promotion zone that use to evaluate the effect of energy conservation programs and to investigate the limit of substation capacity. Moreover, the optimal management of diversity factor is indicated base on the estimated peak demand reduction by energy conservation programs and the annual demand growth of 3 substations. The surveyed results show that the peak demand can be reduced up to 1.97 MW with implementing energy conservation programs which mostly come from electronic ballast replacement measure. However, the analytical results of energy conservation project analysis show that the energy efficiency improvement is still a high potential for Navanakorn industrial promotion zone. Furthermore, the simulation results of multi-scenarios demand side management with the energy conservation programs illustrate that the substations can be supplied industries in Navanakorn industrial promotion zone until 2016 with 96.15% of total transformer capacity in case 5% of peak demand reduction from fully implemented energy conservation programs is achieved. Finally, the effective demand side management programs of the designated factories are the opportunity to extend the new substation","PeriodicalId":272782,"journal":{"name":"Proceedings of the International Conference on Energy and Sustainable Development: Issues and Strategies (ESD 2010)","volume":"86 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the International Conference on Energy and Sustainable Development: Issues and Strategies (ESD 2010)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESD.2010.5598868","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

This paper studies the multi-scenarios of effective demand side management by implementing energy conservation programs in 51 designated factories according the Energy Conservation Promotion Act No. 2 B.E. 2550 (2007). In addition, 5% of peak demand reduction is estimated from the industries in Navanakorn industrial promotion zone that use to evaluate the effect of energy conservation programs and to investigate the limit of substation capacity. Moreover, the optimal management of diversity factor is indicated base on the estimated peak demand reduction by energy conservation programs and the annual demand growth of 3 substations. The surveyed results show that the peak demand can be reduced up to 1.97 MW with implementing energy conservation programs which mostly come from electronic ballast replacement measure. However, the analytical results of energy conservation project analysis show that the energy efficiency improvement is still a high potential for Navanakorn industrial promotion zone. Furthermore, the simulation results of multi-scenarios demand side management with the energy conservation programs illustrate that the substations can be supplied industries in Navanakorn industrial promotion zone until 2016 with 96.15% of total transformer capacity in case 5% of peak demand reduction from fully implemented energy conservation programs is achieved. Finally, the effective demand side management programs of the designated factories are the opportunity to extend the new substation
纳瓦那孔产业促进区多场景需求侧有效管理
本文根据B.E. 2550(2007)第2号节能促进法,通过对51家指定工厂实施节能方案,研究了有效需求侧管理的多情景。此外,估计纳瓦纳孔工业促进区的工业将减少5%的高峰需求,用于评估节能计划的效果和调查变电站容量的限制。最后,结合3个变电站的年需求增长量和节能方案对高峰需求的预估,给出了多样性因子的最优管理。调查结果表明,通过实施节能方案,可减少峰值需求1.97 MW,其中大部分来自电子镇流器更换措施。但节能项目分析结果表明,纳瓦那孔产业促进区能效提升仍有较大潜力。此外,基于节能方案的多场景需求侧管理仿真结果表明,在全面实施节能方案的情况下,在峰值需求减少5%的情况下,到2016年,变电站可以为纳瓦纳孔工业促进区内的工业提供变压器总容量的96.15%。最后,指定工厂的有效需求侧管理方案是扩展新变电站的机会
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信