Magnetic field effects in electrostatic analyzers used for heavy ion beam probe measurements

J. Zieliński, G. Hallock
{"title":"Magnetic field effects in electrostatic analyzers used for heavy ion beam probe measurements","authors":"J. Zieliński, G. Hallock","doi":"10.1109/PLASMA.1989.166227","DOIUrl":null,"url":null,"abstract":"Several recent experiments have heavy-ion-beam-probe diagnostics with analyzers that are located in regions outside of the vacuum system where the magnetic field strength is several hundred gauss or higher. The combination of high secondary particle velocity and high magnetic field inside the analyzer produces magnetic forces that are not negligible when compared to the electric force on these particles. Large errors in the measured plasma potential can result if the magnetic field is not properly taken into account. If the magnetic field is homogeneous, a completely analytic treatment of the analyzer is possible. The analyzer gain and the location and shape of the secondary beam image on the detector plates can be determined without having to calculate the entire trajectory through the analyzer. If the field is not homogeneous, a numerical calculation of the trajectory is necessary.<<ETX>>","PeriodicalId":165717,"journal":{"name":"IEEE 1989 International Conference on Plasma Science","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE 1989 International Conference on Plasma Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PLASMA.1989.166227","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Several recent experiments have heavy-ion-beam-probe diagnostics with analyzers that are located in regions outside of the vacuum system where the magnetic field strength is several hundred gauss or higher. The combination of high secondary particle velocity and high magnetic field inside the analyzer produces magnetic forces that are not negligible when compared to the electric force on these particles. Large errors in the measured plasma potential can result if the magnetic field is not properly taken into account. If the magnetic field is homogeneous, a completely analytic treatment of the analyzer is possible. The analyzer gain and the location and shape of the secondary beam image on the detector plates can be determined without having to calculate the entire trajectory through the analyzer. If the field is not homogeneous, a numerical calculation of the trajectory is necessary.<>
用于重离子束探针测量的静电分析仪中的磁场效应
最近的几个实验使用重离子束探针诊断分析仪,这些分析仪位于真空系统之外的磁场强度为几百高斯或更高的区域。高次级粒子速度和分析器内部的高磁场相结合,产生的磁力与作用在这些粒子上的电场相比是不可忽略的。如果不适当地考虑磁场,测量的等离子体电位会产生很大的误差。如果磁场是均匀的,对分析仪进行完全的分析处理是可能的。无需通过分析仪计算整个轨迹,就可以确定分析仪的增益以及探测器板上二次光束图像的位置和形状。如果场不是均匀的,则需要对轨迹进行数值计算。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信