Power system frequency control using Type-4 wind turbine generators

F. Wilches-Bernal, J. Chow, J. Sanchez-Gasca
{"title":"Power system frequency control using Type-4 wind turbine generators","authors":"F. Wilches-Bernal, J. Chow, J. Sanchez-Gasca","doi":"10.1109/NAPS.2017.8107393","DOIUrl":null,"url":null,"abstract":"System frequency response can be negatively impacted by significant penetration of wind generation. This paper studies the effects of integrating Type-4 full converter wind turbine generators (WTG) on the frequency response of a test system. A controller that enables frequency response in a Type-4 WTG is then proposed to restore and improve the frequency regulation of the system. The design and performance of the proposed controller are demonstrated using linear analysis and nonlinear simulation. The results are then compared with those for Type-3 DFAG frequency regulation technology.","PeriodicalId":296428,"journal":{"name":"2017 North American Power Symposium (NAPS)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 North American Power Symposium (NAPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAPS.2017.8107393","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

System frequency response can be negatively impacted by significant penetration of wind generation. This paper studies the effects of integrating Type-4 full converter wind turbine generators (WTG) on the frequency response of a test system. A controller that enables frequency response in a Type-4 WTG is then proposed to restore and improve the frequency regulation of the system. The design and performance of the proposed controller are demonstrated using linear analysis and nonlinear simulation. The results are then compared with those for Type-3 DFAG frequency regulation technology.
电力系统频率控制采用4型风力发电机
风力发电的显著渗透会对系统频率响应产生负面影响。本文研究了集成4型全变流器风力发电机组对试验系统频率响应的影响。然后,提出了一种使4型WTG的频率响应成为可能的控制器,以恢复和改善系统的频率调节。通过线性分析和非线性仿真验证了所提控制器的设计和性能。然后将结果与3型DFAG频率调节技术的结果进行比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信