A Study of Radiated EMI Predictions from Measured Common-mode Currents for Switching Power Supplies

Warathep Padungtin, V. Tarateeraseth
{"title":"A Study of Radiated EMI Predictions from Measured Common-mode Currents for Switching Power Supplies","authors":"Warathep Padungtin, V. Tarateeraseth","doi":"10.1109/ECTI-CON49241.2020.9158271","DOIUrl":null,"url":null,"abstract":"In this paper, an effectiveness of the classical method proposed by Clayton R. Paul [1]-[3] for estimating radiated electromagnetic interference (EMI) from measured common-mode currents for switching power supply as a noise source is evaluated. The proposed radiated EMI prediction method by Clayton R. Paul [1]-[3] is compared with the testing results in the standard anechoic chamber in order to verify its effectiveness. From the experimental results, it can be concluded that the procedure to predict the radiated EMI of proposed method by [1]-[3] is easy to follow, and it needs only the measured common-mode current using the high-frequency clamp-on current probe. Although, this method can be used as a guideline for radiated EMI prediction, the accuracy of this method needs to be improved.","PeriodicalId":371552,"journal":{"name":"2020 17th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)","volume":"82 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 17th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECTI-CON49241.2020.9158271","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this paper, an effectiveness of the classical method proposed by Clayton R. Paul [1]-[3] for estimating radiated electromagnetic interference (EMI) from measured common-mode currents for switching power supply as a noise source is evaluated. The proposed radiated EMI prediction method by Clayton R. Paul [1]-[3] is compared with the testing results in the standard anechoic chamber in order to verify its effectiveness. From the experimental results, it can be concluded that the procedure to predict the radiated EMI of proposed method by [1]-[3] is easy to follow, and it needs only the measured common-mode current using the high-frequency clamp-on current probe. Although, this method can be used as a guideline for radiated EMI prediction, the accuracy of this method needs to be improved.
开关电源共模电流测量的辐射电磁干扰预测研究
本文评估了Clayton R. Paul[1]-[3]经典方法对作为噪声源的开关电源共模电流辐射电磁干扰(EMI)估计的有效性。将Clayton R. Paul提出的[1]-[3]辐射电磁干扰预测方法与标准暗室的测试结果进行了比较,验证了该方法的有效性。实验结果表明,采用[1]-[3]法预测辐射电磁干扰的步骤简单易行,只需利用高频钳位电流探头测量共模电流即可。虽然该方法可以作为辐射电磁干扰预测的指导,但其精度有待提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信