Evaluation of augmented RIC model of child respiratory impedance based on impulse oscillometry data

A. Rajagiri, B. Diong
{"title":"Evaluation of augmented RIC model of child respiratory impedance based on impulse oscillometry data","authors":"A. Rajagiri, B. Diong","doi":"10.1109/TPSD.2006.5507416","DOIUrl":null,"url":null,"abstract":"The augmented RIC model of the respiratory system is described and analyzed in this work. The parameters for this and four other well-known respiratory system models were estimated using impulse oscillometry data, obtained from both healthy and asthmatic children, in order to compare the modeling errors and the models' fidelity. Of these five models, the augmented RIC model ranked in the middle in terms of magnitude of modeling error for the given data, but other factors in its favor were determined. Hence it is the most reasonable model to use for further studies to improve the detection and diagnosis of respiratory diseases.","PeriodicalId":385396,"journal":{"name":"2006 IEEE Region 5 Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2006-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE Region 5 Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TPSD.2006.5507416","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

The augmented RIC model of the respiratory system is described and analyzed in this work. The parameters for this and four other well-known respiratory system models were estimated using impulse oscillometry data, obtained from both healthy and asthmatic children, in order to compare the modeling errors and the models' fidelity. Of these five models, the augmented RIC model ranked in the middle in terms of magnitude of modeling error for the given data, but other factors in its favor were determined. Hence it is the most reasonable model to use for further studies to improve the detection and diagnosis of respiratory diseases.
基于脉冲振荡测量数据的儿童呼吸阻抗增强RIC模型评价
本文对呼吸系统的增强RIC模型进行了描述和分析。利用从健康儿童和哮喘儿童中获得的脉冲振荡测量数据估计了该模型和其他四种知名呼吸系统模型的参数,以比较建模误差和模型的保真度。在这五种模型中,增强型RIC模型在给定数据的建模误差程度方面排名中间,但确定了其他有利于其的因素。因此,该模型可用于进一步研究,以提高呼吸系统疾病的检测和诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信