Fernando Bagalciague, C. S. Roman, M. Arocena, H. Suarez, Enrique D. Ferreira, N. Pena
{"title":"Unstable gait assessment with a portable analysis system","authors":"Fernando Bagalciague, C. S. Roman, M. Arocena, H. Suarez, Enrique D. Ferreira, N. Pena","doi":"10.1109/I2MTC.2014.6860729","DOIUrl":null,"url":null,"abstract":"An inertial sensor based gait analysis system is presented. Standard gait parameters, feet and hip ranges of motion (ROMs) and hip peak velocities, in medio-lateral and anterior-posterior directions, are validated in different experiments, including footswitches, treadmill, long walk and motion capture system. The mean of relative root-mean-square errors for gait cycle, stance, stride length, stride velocity and feet ROMs in low and medium velocities, is below 5%. Standard gait parameters for a control group of fourteen healthy young adults are compared with previous studies, showing consistent results. This control group is also compared to a group of eleven unstable adults to determine main discrimination parameters. Significant differences (p <; 0.05) are found for cadence, normalized speed, normalized stride length, anterior-posterior feet ROM, medio-lateral hip ROM and medio-lateral hip peak velocity. These results suggest that basic gait parameters, together with feet and hip ROMs and peak velocities, might differentiate unstable subjects from healthy young adults.","PeriodicalId":331484,"journal":{"name":"2014 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings","volume":"256 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/I2MTC.2014.6860729","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
An inertial sensor based gait analysis system is presented. Standard gait parameters, feet and hip ranges of motion (ROMs) and hip peak velocities, in medio-lateral and anterior-posterior directions, are validated in different experiments, including footswitches, treadmill, long walk and motion capture system. The mean of relative root-mean-square errors for gait cycle, stance, stride length, stride velocity and feet ROMs in low and medium velocities, is below 5%. Standard gait parameters for a control group of fourteen healthy young adults are compared with previous studies, showing consistent results. This control group is also compared to a group of eleven unstable adults to determine main discrimination parameters. Significant differences (p <; 0.05) are found for cadence, normalized speed, normalized stride length, anterior-posterior feet ROM, medio-lateral hip ROM and medio-lateral hip peak velocity. These results suggest that basic gait parameters, together with feet and hip ROMs and peak velocities, might differentiate unstable subjects from healthy young adults.