A compact ECoG system with bidirectional capacitive data telemetry

R. Mohammadi, Mohammad A. Sharif, Ali Kia, Masoud Hoveidar-Sefid, A. M. Sodagar, E. Nadimi
{"title":"A compact ECoG system with bidirectional capacitive data telemetry","authors":"R. Mohammadi, Mohammad A. Sharif, Ali Kia, Masoud Hoveidar-Sefid, A. M. Sodagar, E. Nadimi","doi":"10.1109/BioCAS.2014.6981797","DOIUrl":null,"url":null,"abstract":"This paper reports on the design, development, and test of a compact battery-powered wireless electrocorticography (ECoG) system. The system benefits from a new design for capacitive links that allows for bidirectional data exchange between the implant unit and the external world. A stainless steel package is designed and machined to contain a rigid 8-channel microelectrode array (MEA), a main electronic board, two batteries, and a board realizing the internal side of the capacitive link. In vitro operation of the system for the recording of prerecorded ECoG data, along with its wireless bidirectional data exchange via the proposed 4-contact capacitive link was demonstrated.","PeriodicalId":414575,"journal":{"name":"2014 IEEE Biomedical Circuits and Systems Conference (BioCAS) Proceedings","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Biomedical Circuits and Systems Conference (BioCAS) Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BioCAS.2014.6981797","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

This paper reports on the design, development, and test of a compact battery-powered wireless electrocorticography (ECoG) system. The system benefits from a new design for capacitive links that allows for bidirectional data exchange between the implant unit and the external world. A stainless steel package is designed and machined to contain a rigid 8-channel microelectrode array (MEA), a main electronic board, two batteries, and a board realizing the internal side of the capacitive link. In vitro operation of the system for the recording of prerecorded ECoG data, along with its wireless bidirectional data exchange via the proposed 4-contact capacitive link was demonstrated.
具有双向电容式数据遥测的紧凑ECoG系统
本文报道了一种紧凑的电池供电无线皮质电图(ECoG)系统的设计、开发和测试。该系统得益于电容链路的新设计,允许植入单元与外部世界之间的双向数据交换。设计和加工了一个不锈钢封装,包含一个刚性的8通道微电极阵列(MEA),一个主电子板,两个电池和一个实现电容链路内部的板。该系统在体外运行,用于记录预先录制的ECoG数据,以及通过拟议的4触点电容链路进行无线双向数据交换。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信