Imaging of pulmonary edema with microwaves — Preliminary investigation

Semih Doğu, Ismail Dilman, M. Çayören, I. Akduman
{"title":"Imaging of pulmonary edema with microwaves — Preliminary investigation","authors":"Semih Doğu, Ismail Dilman, M. Çayören, I. Akduman","doi":"10.5072/ZENODO.56042","DOIUrl":null,"url":null,"abstract":"We consider microwave imaging of pulmonary edema which is a critical medical condition which manifests itself as a water accumulation in the human lungs. In order to detect water accumulation in the human lungs, we implement a microwave inversion scheme based on Born iterative method (BIM). To that end, a realistic human torso phantom is used and dielectric parameters of tissues and organs are estimated via Cole-Cole model at desired frequency. Then, scattered electric field is calculated synthetically by method of moments. Simulations are performed at 350 MHz and the region between phantom and antennas are surrounded by a dielectric material with a permittivity of 30. In the numerical results section, performance assessment of BIM is carried for two cases. The numerical results suggest that the BIM is capable of imaging water accumulation in the human lungs.","PeriodicalId":395108,"journal":{"name":"2017 10th International Conference on Electrical and Electronics Engineering (ELECO)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 10th International Conference on Electrical and Electronics Engineering (ELECO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5072/ZENODO.56042","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

We consider microwave imaging of pulmonary edema which is a critical medical condition which manifests itself as a water accumulation in the human lungs. In order to detect water accumulation in the human lungs, we implement a microwave inversion scheme based on Born iterative method (BIM). To that end, a realistic human torso phantom is used and dielectric parameters of tissues and organs are estimated via Cole-Cole model at desired frequency. Then, scattered electric field is calculated synthetically by method of moments. Simulations are performed at 350 MHz and the region between phantom and antennas are surrounded by a dielectric material with a permittivity of 30. In the numerical results section, performance assessment of BIM is carried for two cases. The numerical results suggest that the BIM is capable of imaging water accumulation in the human lungs.
微波成像肺水肿的初步研究
我们考虑肺水肿的微波成像,这是一种严重的医学状况,表现为人体肺部积水。为了检测人体肺部积水量,我们实现了一种基于Born迭代法(BIM)的微波反演方案。为此,使用了一个真实的人体躯干模型,并通过Cole-Cole模型在期望频率下估计组织和器官的介电参数。然后,采用矩量法综合计算散射电场。在350 MHz的频率下进行仿真,在模体和天线之间的区域被介电常数为30的介电材料包围。在数值结果部分,对两种情况进行了BIM的性能评估。数值结果表明,BIM能够对人体肺部积水进行成像。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信