{"title":"Detection of micro calcifications of mammographic images","authors":"T. Maruyama, H. Yamamoto","doi":"10.1109/IST.2007.379574","DOIUrl":null,"url":null,"abstract":"Mammographic X-ray equipment uses the radiographic grid in order to remove the scatter radiation and to improve image contrast. The gridlines cause striped lines to appear on the film and may impair diagnostic information. In this study, we propose a new method which reduces noise caused by the gridlines of the mammographic film using digital image processing techniques. We exposed the phantom and chose the region of micro calcifications. We performed the V-filtering and median filtering to reduce noises. By using image filtering, we could increase the signal to noise ratio. The results suggested that the accuracy of the mammographic diagnosis could be improved by proposed method.","PeriodicalId":329519,"journal":{"name":"2007 IEEE International Workshop on Imaging Systems and Techniques","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE International Workshop on Imaging Systems and Techniques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IST.2007.379574","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Mammographic X-ray equipment uses the radiographic grid in order to remove the scatter radiation and to improve image contrast. The gridlines cause striped lines to appear on the film and may impair diagnostic information. In this study, we propose a new method which reduces noise caused by the gridlines of the mammographic film using digital image processing techniques. We exposed the phantom and chose the region of micro calcifications. We performed the V-filtering and median filtering to reduce noises. By using image filtering, we could increase the signal to noise ratio. The results suggested that the accuracy of the mammographic diagnosis could be improved by proposed method.
乳房x线影像微钙化的检测
乳房x线摄影设备使用放射网格来消除散射辐射并提高图像对比度。网格线导致条纹线出现在胶片上,并可能损害诊断信息。在这项研究中,我们提出了一种利用数字图像处理技术降低乳房x线片网格线引起的噪声的新方法。我们暴露了幻肢并选择了微钙化区域。我们通过v滤波和中值滤波来降低噪声。通过对图像进行滤波,可以提高信号的信噪比。结果表明,该方法可提高乳腺x线摄影诊断的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信