{"title":"PERBANDINGAN KEKUATAN BETON DENGAN CAMPURAN DRAMIX STEEL FIBER DAN TULANGAN WIREMESH PADA RIGID PAVEMENT (Comparison of the Strength of Concrete with a mixture of Dramix Steel Fiber and Wiremesh Reinforcement on Rigid Pavement)","authors":"A TwoPujiGuntur, Yosef Cahyo, Sigit Winarto","doi":"10.30737/jurmateks.v1i2.419","DOIUrl":null,"url":null,"abstract":"ABSTRACTConcrete has a weakness that is having a low tensile strength and brittle so that the concrete is given steel reinforcement to anticipate it. In this study, the concrete mixture was added with dramix steel fiber. This addition was carried out to study and determine the effect of dramix steel fiber on compressive strength, flexural strength on normal quality concrete with the addition of 0%, 10%, 20% and 30% in compressive loads. Compressive strength specimens in the form of cylinders with a diameter of 15 cm and a height of 30 cm and bending strength test specimens in the form of blocks with a length of 60 cm, width of 15 cm and height of 15 cm. Testing is done after 28 days. Concrete with the addition of dramix steel fiber is 30% more capable of producing a higher compressive strength than the others. The addition of dramix steel fiber resulted in an average compressive strength of 0%, 29.07 MPa, 10%, 29.33 MPa, 20%, 29.40 MPa, 30%, 29.58 MPa. For the highest flexural strength of concrete in the 15/15/60 beam sample, that is in the concrete mixture and the addition of dramix steel fiber of 5.44 MPa, it is higher than the addition of reinforcement iron m8, which is 4.96 MPa.Keywords:Dramix Steel Fiber, compressive strength, concrete flexural strength, m8 wiremesh","PeriodicalId":382880,"journal":{"name":"Jurnal Manajemen Teknologi & Teknik Sipil","volume":"150 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Manajemen Teknologi & Teknik Sipil","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30737/jurmateks.v1i2.419","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

ABSTRACTConcrete has a weakness that is having a low tensile strength and brittle so that the concrete is given steel reinforcement to anticipate it. In this study, the concrete mixture was added with dramix steel fiber. This addition was carried out to study and determine the effect of dramix steel fiber on compressive strength, flexural strength on normal quality concrete with the addition of 0%, 10%, 20% and 30% in compressive loads. Compressive strength specimens in the form of cylinders with a diameter of 15 cm and a height of 30 cm and bending strength test specimens in the form of blocks with a length of 60 cm, width of 15 cm and height of 15 cm. Testing is done after 28 days. Concrete with the addition of dramix steel fiber is 30% more capable of producing a higher compressive strength than the others. The addition of dramix steel fiber resulted in an average compressive strength of 0%, 29.07 MPa, 10%, 29.33 MPa, 20%, 29.40 MPa, 30%, 29.58 MPa. For the highest flexural strength of concrete in the 15/15/60 beam sample, that is in the concrete mixture and the addition of dramix steel fiber of 5.44 MPa, it is higher than the addition of reinforcement iron m8, which is 4.96 MPa.Keywords:Dramix Steel Fiber, compressive strength, concrete flexural strength, m8 wiremesh
【摘要】混凝土的弱点是抗拉强度低,易碎,因此混凝土被赋予钢筋来预测它。在本研究中,掺加了掺量为dramix钢纤维的混凝土混合料。本试验研究了抗压荷载下掺量分别为0%、10%、20%、30%的dramix钢纤维对普通质量混凝土抗压强度、抗弯强度的影响。抗压强度试件为直径15cm、高30cm的圆柱体,抗折强度试件为长60cm、宽15cm、高15cm的块状试件。28天后进行测试。掺加dramix钢纤维的混凝土抗压强度比其他混凝土高30%。掺加dramix钢纤维的平均抗压强度分别为0%、29.07 MPa、10%、29.33 MPa、20%、29.40 MPa、30%、29.58 MPa。对于15/15/60梁试件中混凝土的最高抗弯强度,即在混凝土混合料中掺加掺量为5.44 MPa的掺量,高于配筋铁m8的掺量4.96 MPa。关键词:Dramix钢纤维,抗压强度,混凝土抗弯强度,m8钢丝网
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书