{"title":"Fault estimation with analytical cable model for MMC-HVDC in offshore applications","authors":"J. Bapiraju, P. Manohar","doi":"10.1109/APPEEC.2017.8308982","DOIUrl":null,"url":null,"abstract":"Reliable operation of offshore windfarms is very critical and it depends on efficient operation of each component. Underwater cable is one of key element which has less access to measurements except at both ends of the transmission. In this paper, a detailed cable model is considered to analyse the nature of fault from signatures of measurements in offshore Multi-Modular Converter High Voltage DC (MMC-HVDC) systems. The cable model representing the frequency dependent characteristics is used in this paper. The estimated model is emulated inside the controller while controller controls and gets feedback from the physical model. Both the model results are initially verified in all healthy states and all operating modes. Different abnormal conditions including short circuit and open circuit phenomenon are created on the simulated cable model and analysed. A novel method of identifying these faults with the available measurements using estimated cable model is proposed. This is further verified with the simulation results.","PeriodicalId":247669,"journal":{"name":"2017 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APPEEC.2017.8308982","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Reliable operation of offshore windfarms is very critical and it depends on efficient operation of each component. Underwater cable is one of key element which has less access to measurements except at both ends of the transmission. In this paper, a detailed cable model is considered to analyse the nature of fault from signatures of measurements in offshore Multi-Modular Converter High Voltage DC (MMC-HVDC) systems. The cable model representing the frequency dependent characteristics is used in this paper. The estimated model is emulated inside the controller while controller controls and gets feedback from the physical model. Both the model results are initially verified in all healthy states and all operating modes. Different abnormal conditions including short circuit and open circuit phenomenon are created on the simulated cable model and analysed. A novel method of identifying these faults with the available measurements using estimated cable model is proposed. This is further verified with the simulation results.
海上MMC-HVDC的解析电缆模型故障估计
海上风电场的可靠运行至关重要,它取决于各部件的高效运行。水下电缆是除传输两端外很少被测量的关键元件之一。本文考虑了一种详细的电缆模型,从海上多模块变换器高压直流(MMC-HVDC)系统的测量特征来分析故障的性质。本文采用表征频率相关特性的电缆模型。当控制器控制并从物理模型获得反馈时,在控制器内部对估计模型进行仿真。在所有健康状态和所有操作模式下对模型结果进行初步验证。在模拟的电缆模型上产生了短路、断路等不同的异常情况,并进行了分析。提出了一种利用估计电缆模型利用现有测量值识别故障的新方法。仿真结果进一步验证了这一点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信