{"title":"Design of an Impulsive Offset-Free MHE/ZMPC Scheme For Type 1 Diabetes Treatment","authors":"M. F. Villa-Tamayo, P. Rivadeneira","doi":"10.1109/CCAC.2019.8921327","DOIUrl":null,"url":null,"abstract":"Type 1 diabetes treatment can be modeled as an impulsive control system because insulin doses are administered to the patient as small pulses and not as a continuous or discrete input. Therefore, an impulsive scheme of estimation and control is needed. Here, an impulsive MHE is designed and it is coupled with a zone MPC which allows to include the system constraints in both estimation and control problems. In addition, an offset-free strategy is added to compensate the effects of the inherent plant-model mismatch given by the physiological changes of the patient. These variations can generate an inaccurate insulin administration that produces an offset in relation to the nor-moglycemia zone and leads to hypoglycemia or hyperglycemia events. The offset-free MHE/ZMPC formulation reestablishes the normoglycemia behavior by compensating parameter variations. Variations up to 30% were considered, as well as the sensor noise from the continuous glucose monitor.","PeriodicalId":184764,"journal":{"name":"2019 IEEE 4th Colombian Conference on Automatic Control (CCAC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 4th Colombian Conference on Automatic Control (CCAC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCAC.2019.8921327","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Type 1 diabetes treatment can be modeled as an impulsive control system because insulin doses are administered to the patient as small pulses and not as a continuous or discrete input. Therefore, an impulsive scheme of estimation and control is needed. Here, an impulsive MHE is designed and it is coupled with a zone MPC which allows to include the system constraints in both estimation and control problems. In addition, an offset-free strategy is added to compensate the effects of the inherent plant-model mismatch given by the physiological changes of the patient. These variations can generate an inaccurate insulin administration that produces an offset in relation to the nor-moglycemia zone and leads to hypoglycemia or hyperglycemia events. The offset-free MHE/ZMPC formulation reestablishes the normoglycemia behavior by compensating parameter variations. Variations up to 30% were considered, as well as the sensor noise from the continuous glucose monitor.
1型糖尿病无脉冲偏移MHE/ZMPC治疗方案的设计
1型糖尿病的治疗可以建模为脉冲控制系统,因为胰岛素剂量以小脉冲的形式给予患者,而不是连续或离散的输入。因此,需要一种脉冲估计和控制方案。在这里,设计了一个脉冲MHE,它与一个区域MPC相结合,允许在估计和控制问题中包含系统约束。此外,增加了一个无偏移策略,以补偿患者生理变化所带来的固有植物模型不匹配的影响。这些变化会导致不准确的胰岛素给药,产生与无血糖区相关的偏移,导致低血糖或高血糖事件。无偏移的MHE/ZMPC配方通过补偿参数变化重建了正常血糖行为。考虑了高达30%的变化,以及来自连续血糖监测仪的传感器噪声。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信