Endoscopic Endonasal Accessibility and Maneuverability Around the Internal Carotid Artery from Distal Dural Ring to Foramen Lacerum: Cadaveric Study

Alhusain Nagm
{"title":"Endoscopic Endonasal Accessibility and Maneuverability Around the Internal Carotid Artery from Distal Dural Ring to Foramen Lacerum: Cadaveric Study","authors":"Alhusain Nagm","doi":"10.58675/2682-339x.1681","DOIUrl":null,"url":null,"abstract":"Background : Expanded-endoscopic endonasal approaches (eEEA) to surgical targets around the internal carotid artery (ICA) remain inspiring and necessitate a special learning curve. Materials and methods : Six formalin-fi xed heads were dissected to study the 360 (cid:1) accessibility and maneuverability around ICAs from the distal dural ring to the foramen lacerum on each side ( n ¼ 12) via eEEA. The ICA course was divided into three segments: ICA in cavernous sinus, paraclival-ICA, and lacerum-ICA. Following total exposure of each ICA, the three-dimensional (3D ¼ medial/lateral, super fi cial/deep, and above/below) anatomical targets ( n ¼ 35) around each ICA were evaluated. The data were collected and analyzed. Results : Distinctively, we included 35 anatomical targets (pertinent to ICA in cavernous sinus, paraclival-ICA, and lacerum-ICA were 16, 10, and 9, respectively) in 360 (cid:1) around every ICA ( n ¼ 12) from the distal dural ring to foramen lacerum. Although reasonable visual validation was possible for all targets, microdissections were safely achievable for 19 (54.3%) targets through full or limited surgical freedom in 73.7 and 26.3%, respectively. In the remaining 45.7%, the accessibility to targets was abandoned due to hazardous manipulation. The most unreachable targets were around the lacerum-ICA (55.6%) with extremely restricted maneuverability (75%). However, favorable accessibility (60%) and full surgical freedom (100%) were around the paraclival-ICA. Conclusion : This study delivers a distinctive view to appreciate the degree of complexity and invasiveness in relation to the degree of surgical freedom around ICA via eEEA.","PeriodicalId":256725,"journal":{"name":"Al-Azhar International Medical Journal","volume":"96 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Al-Azhar International Medical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.58675/2682-339x.1681","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Background : Expanded-endoscopic endonasal approaches (eEEA) to surgical targets around the internal carotid artery (ICA) remain inspiring and necessitate a special learning curve. Materials and methods : Six formalin-fi xed heads were dissected to study the 360 (cid:1) accessibility and maneuverability around ICAs from the distal dural ring to the foramen lacerum on each side ( n ¼ 12) via eEEA. The ICA course was divided into three segments: ICA in cavernous sinus, paraclival-ICA, and lacerum-ICA. Following total exposure of each ICA, the three-dimensional (3D ¼ medial/lateral, super fi cial/deep, and above/below) anatomical targets ( n ¼ 35) around each ICA were evaluated. The data were collected and analyzed. Results : Distinctively, we included 35 anatomical targets (pertinent to ICA in cavernous sinus, paraclival-ICA, and lacerum-ICA were 16, 10, and 9, respectively) in 360 (cid:1) around every ICA ( n ¼ 12) from the distal dural ring to foramen lacerum. Although reasonable visual validation was possible for all targets, microdissections were safely achievable for 19 (54.3%) targets through full or limited surgical freedom in 73.7 and 26.3%, respectively. In the remaining 45.7%, the accessibility to targets was abandoned due to hazardous manipulation. The most unreachable targets were around the lacerum-ICA (55.6%) with extremely restricted maneuverability (75%). However, favorable accessibility (60%) and full surgical freedom (100%) were around the paraclival-ICA. Conclusion : This study delivers a distinctive view to appreciate the degree of complexity and invasiveness in relation to the degree of surgical freedom around ICA via eEEA.
从硬脑膜远端环到撕裂孔的内窥镜下颈动脉周围的可达性和可操作性:尸体研究
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信