Jianrong Chen, K. Nagao, Y. Tomotake, K. Oka, M. Hada, T. Ichikawa
{"title":"Influence of a Vent Hole on the Retentive Force of a Cement-retained Superstructure before/after Thermocycling","authors":"Jianrong Chen, K. Nagao, Y. Tomotake, K. Oka, M. Hada, T. Ichikawa","doi":"10.2186/PRP.5.157","DOIUrl":null,"url":null,"abstract":"Purpose: The purpose of this study was to evaluate the influence of a vent hole on the retentive force of a cement-retained superstructure to an abutment.Methods: The retentive force of superstructures with/without a vent hole, retained using one of two luting cements, was measured using a universal testing machine both before and after thermocyclingResults: The retentive force of the cement-retained superstructure with the vent hole was greater than that of the cement-retained superstructure without the vent hole. While the retentive force decreased significantly after thermocycling, the size of the vent hole had little influence on the retentive force.Conclusion: It was concluded that placement of a vent hole in the superstructure is useful, with little adverse effect on the retentive force of the restoration.","PeriodicalId":306414,"journal":{"name":"Prosthodontic Research & Practice","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Prosthodontic Research & Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2186/PRP.5.157","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Purpose: The purpose of this study was to evaluate the influence of a vent hole on the retentive force of a cement-retained superstructure to an abutment.Methods: The retentive force of superstructures with/without a vent hole, retained using one of two luting cements, was measured using a universal testing machine both before and after thermocyclingResults: The retentive force of the cement-retained superstructure with the vent hole was greater than that of the cement-retained superstructure without the vent hole. While the retentive force decreased significantly after thermocycling, the size of the vent hole had little influence on the retentive force.Conclusion: It was concluded that placement of a vent hole in the superstructure is useful, with little adverse effect on the retentive force of the restoration.