Fault-tolerant topology of a grid-connected PV inverter coupled by a Scott transformer

Mai Tuan Dat, T. Wijnhoven, J. Driesen
{"title":"Fault-tolerant topology of a grid-connected PV inverter coupled by a Scott transformer","authors":"Mai Tuan Dat, T. Wijnhoven, J. Driesen","doi":"10.1109/ASSCC.2012.6523306","DOIUrl":null,"url":null,"abstract":"A grid-connected photovoltaic(PV) power plant is mainly based on power electronics equipments which are considered as the most vulnerable parts in a PV system. In order to increase the reliability of modular grid-connected PV panel, a solution by using a Scott transformer is presented to reduce the number of switches and to continuously operate the PV system in case of switch-failures of the power converter. The three-phase type PV inverter is analyzed in the normal and fault-operation. The simulation has shown that fault tolerance can be achieved with the proposed system configuration to give a redundancy of power switches in an Integrated power electronic module. Index Terms-Power converter, Scott transformer, redundant components, fault-tolerant, grid-connected inverter, grid-tie, reference frame, Clarke transformation.","PeriodicalId":341348,"journal":{"name":"2012 10th International Power & Energy Conference (IPEC)","volume":"204 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 10th International Power & Energy Conference (IPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASSCC.2012.6523306","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

A grid-connected photovoltaic(PV) power plant is mainly based on power electronics equipments which are considered as the most vulnerable parts in a PV system. In order to increase the reliability of modular grid-connected PV panel, a solution by using a Scott transformer is presented to reduce the number of switches and to continuously operate the PV system in case of switch-failures of the power converter. The three-phase type PV inverter is analyzed in the normal and fault-operation. The simulation has shown that fault tolerance can be achieved with the proposed system configuration to give a redundancy of power switches in an Integrated power electronic module. Index Terms-Power converter, Scott transformer, redundant components, fault-tolerant, grid-connected inverter, grid-tie, reference frame, Clarke transformation.
斯科特变压器耦合并网光伏逆变器的容错拓扑
光伏并网电站主要以电力电子设备为基础,而电力电子设备是光伏系统中最脆弱的部件。为了提高模块化光伏并网板的可靠性,提出了一种采用Scott变压器的方案,在电源变流器开关故障的情况下,减少开关数量,保证光伏系统的持续运行。对三相型光伏逆变器的正常运行和故障运行进行了分析。仿真结果表明,所提出的系统配置可以实现容错,从而在集成电力电子模块中提供冗余的电源开关。索引术语-电源变换器,斯科特变压器,冗余元件,容错,并网逆变器,并网,参考框架,克拉克变换。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信