Real Time Implementation and Experiments of Multi-channel Active Noise Control System for ICU

Lichuan Liu, Qiang Su, Wei Li, S. Kuo
{"title":"Real Time Implementation and Experiments of Multi-channel Active Noise Control System for ICU","authors":"Lichuan Liu, Qiang Su, Wei Li, S. Kuo","doi":"10.1109/EIT51626.2021.9491916","DOIUrl":null,"url":null,"abstract":"The purpose of this study is to help reduce high noise levels experienced by patients in intensive care unit (ICU) environments. The study has designed and developed the active noise control (ANC) system based on filtered x least mean square (FxLMS) to reduce the interfering noise around ICU patients’ beds. A multi-channel feed-forward ANC algorithm has been implemented in a real-time digital signal processing system based on TMS320 DSP C6713. This noise cancellation system has been tested in a patient bed with recorded real ICU noise as the noise source to mimic the ICU noisy environment. The experiment setup has been presented. The real-time experiment results show that ANC is a promising solution to solve high noise level problem inside ICU.","PeriodicalId":162816,"journal":{"name":"2021 IEEE International Conference on Electro Information Technology (EIT)","volume":"52 3","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE International Conference on Electro Information Technology (EIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIT51626.2021.9491916","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The purpose of this study is to help reduce high noise levels experienced by patients in intensive care unit (ICU) environments. The study has designed and developed the active noise control (ANC) system based on filtered x least mean square (FxLMS) to reduce the interfering noise around ICU patients’ beds. A multi-channel feed-forward ANC algorithm has been implemented in a real-time digital signal processing system based on TMS320 DSP C6713. This noise cancellation system has been tested in a patient bed with recorded real ICU noise as the noise source to mimic the ICU noisy environment. The experiment setup has been presented. The real-time experiment results show that ANC is a promising solution to solve high noise level problem inside ICU.
ICU多通道有源噪声控制系统的实时实现与实验
本研究的目的是帮助降低重症监护病房(ICU)环境中患者所经历的高噪音水平。本研究设计并开发了基于滤波x最小均方(FxLMS)的主动噪声控制(ANC)系统,以降低ICU患者病床周围的干扰噪声。在基于TMS320 DSP C6713的实时数字信号处理系统中实现了一种多通道前馈ANC算法。该降噪系统已在病床上进行了测试,以记录的真实ICU噪声为噪声源,模拟ICU噪声环境。给出了实验装置。实时实验结果表明,ANC是解决ICU内部高噪声问题的一种很有前途的解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信