{"title":"LPRS analysis of sliding mode control of a boost converter","authors":"Ayman AlZawaideh, I. Boiko","doi":"10.1109/VSS.2018.8460258","DOIUrl":null,"url":null,"abstract":"This paper provides analysis of a boost converter dynamics using the locus of a perturbed relay system (LPRS) method. This method allows one to determine the exact amplitude and frequency of the output voltage oscillations, as well as it describes the external signal propagation throughout the system. The efficiency of the proposed approach is verified experimentally and via simulations.","PeriodicalId":127777,"journal":{"name":"2018 15th International Workshop on Variable Structure Systems (VSS)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 15th International Workshop on Variable Structure Systems (VSS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/VSS.2018.8460258","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
This paper provides analysis of a boost converter dynamics using the locus of a perturbed relay system (LPRS) method. This method allows one to determine the exact amplitude and frequency of the output voltage oscillations, as well as it describes the external signal propagation throughout the system. The efficiency of the proposed approach is verified experimentally and via simulations.