{"title":"Influence Analysis of Mutual Coupling Effects between a High-Voltage Transmission Line and a Fibre-optic Cable with a Conductive Support Element","authors":"I. Zālītis, A. Dolgicers, J. Kozadajevs","doi":"10.1109/AIEEE.2018.8592447","DOIUrl":null,"url":null,"abstract":"Applications of fibre-optic cables with conductive support elements for installations on high-voltage line towers are not as common as all-dielectric cable designs. Therefore, the influence of high-voltage lines on such cables has not been studied widely. In this paper, a lumped parameter model in phase coordinates is developed to determine the current and voltage of a conductive element of a fibre-optic cable section installed on a high-voltage line. Methods required to determine the parameters of the mutual induction and electrostatic links for this model are provided. A case study is performed for a figure-8 cable application on a 330 kV line, which indicates that the induced voltage to earth is a significant threat to the cable if the conductive element is insulated from the earth. The demonstrated approach can be used for analysing the influence of a high-voltage line on any elongated conductive object.","PeriodicalId":198244,"journal":{"name":"2018 IEEE 6th Workshop on Advances in Information, Electronic and Electrical Engineering (AIEEE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE 6th Workshop on Advances in Information, Electronic and Electrical Engineering (AIEEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AIEEE.2018.8592447","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Applications of fibre-optic cables with conductive support elements for installations on high-voltage line towers are not as common as all-dielectric cable designs. Therefore, the influence of high-voltage lines on such cables has not been studied widely. In this paper, a lumped parameter model in phase coordinates is developed to determine the current and voltage of a conductive element of a fibre-optic cable section installed on a high-voltage line. Methods required to determine the parameters of the mutual induction and electrostatic links for this model are provided. A case study is performed for a figure-8 cable application on a 330 kV line, which indicates that the induced voltage to earth is a significant threat to the cable if the conductive element is insulated from the earth. The demonstrated approach can be used for analysing the influence of a high-voltage line on any elongated conductive object.