The Architecture Of A Fault-tolerant Cached RAID Controller

J. Menon, Jim Cortney
{"title":"The Architecture Of A Fault-tolerant Cached RAID Controller","authors":"J. Menon, Jim Cortney","doi":"10.1109/ISCA.1993.698547","DOIUrl":null,"url":null,"abstract":"RAID-5 arrays need 4 disk accesses to update a data block—2 to read old data and parity, and 2 to write new data and parity. Schemes previously proposed to improve the update performance of such arrays are the Log-Structured File System [10] and the Floating Parity Approach [6]. Here, we consider a third approach, called Fast Write, which eliminates disk time from the host response time to a write, by using a Non-Volatile Cache in the disk array controller. We examine three alternatives for handling Fast Writes and describe a hierarchy of destage algorithms with increasing robustness to failures. These destage algorithms are compared against those that would be used by a disk controller employing mirroring. We show that array controllers require considerably more (2 to 3 times more) bus bandwidth and memory bandwidth than do disk controllers that employ mirroring. So, array controllers that use parity are likely to be more expensive than controllers that do mirroring, though mirroring is more expensive when both controllers and disks are considered.","PeriodicalId":410022,"journal":{"name":"Proceedings of the 20th Annual International Symposium on Computer Architecture","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1993-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"96","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 20th Annual International Symposium on Computer Architecture","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISCA.1993.698547","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 96

Abstract

RAID-5 arrays need 4 disk accesses to update a data block—2 to read old data and parity, and 2 to write new data and parity. Schemes previously proposed to improve the update performance of such arrays are the Log-Structured File System [10] and the Floating Parity Approach [6]. Here, we consider a third approach, called Fast Write, which eliminates disk time from the host response time to a write, by using a Non-Volatile Cache in the disk array controller. We examine three alternatives for handling Fast Writes and describe a hierarchy of destage algorithms with increasing robustness to failures. These destage algorithms are compared against those that would be used by a disk controller employing mirroring. We show that array controllers require considerably more (2 to 3 times more) bus bandwidth and memory bandwidth than do disk controllers that employ mirroring. So, array controllers that use parity are likely to be more expensive than controllers that do mirroring, though mirroring is more expensive when both controllers and disks are considered.
容错缓存RAID控制器的结构
RAID-5阵列需要4次磁盘访问来更新数据块—2次读取旧数据和奇偶校验,2次写入新数据和奇偶校验。以前提出的改进此类数组更新性能的方案是日志结构文件系统[10]和浮动奇偶校验方法[6]。这里,我们考虑第三种方法,称为Fast Write,它通过在磁盘阵列控制器中使用非易失性缓存,消除了从主机响应时间到写入的磁盘时间。我们研究了处理快速写入的三种替代方案,并描述了具有增强故障鲁棒性的破坏算法的层次结构。将这些破坏算法与采用镜像的磁盘控制器所使用的算法进行比较。我们表明,阵列控制器比采用镜像的磁盘控制器需要更多的总线带宽和内存带宽(多2到3倍)。因此,使用奇偶校验的阵列控制器可能比使用镜像的控制器成本更高,尽管在同时考虑控制器和磁盘时,镜像成本更高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信