Biocompatibility of CaO-Na2O-SiO2/TiO2 Glass Ceramic Scaffolds for Orthopaedic Applications

A. Wren, A. Coughlan, K. Smale, S. Misture, B. Mahon, O. Clarkin, M. Towler
{"title":"Biocompatibility of CaO-Na2O-SiO2/TiO2 Glass Ceramic Scaffolds for Orthopaedic Applications","authors":"A. Wren, A. Coughlan, K. Smale, S. Misture, B. Mahon, O. Clarkin, M. Towler","doi":"10.1109/NEBEC.2013.56","DOIUrl":null,"url":null,"abstract":"This work aims to determine the effect of substituting TiO<sub>2</sub>for SiO<sub>2</sub> in a 0.62SiO<sub>2</sub>-Na<sub>2</sub>O-0.24CaO based glass-ceramic scaffold. High temperature X-ray Diffraction (HT-XRD) was used to determine the sintering temperature (700°C). Both optical microscopy and x-ray micotomography was used to determine the average pore size (540-680μm) of each scaffold. Cytocompatibility of each scaffold was conducted using murine mesenchymal stem cells.","PeriodicalId":153112,"journal":{"name":"2013 39th Annual Northeast Bioengineering Conference","volume":"12 4","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 39th Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBEC.2013.56","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This work aims to determine the effect of substituting TiO2for SiO2 in a 0.62SiO2-Na2O-0.24CaO based glass-ceramic scaffold. High temperature X-ray Diffraction (HT-XRD) was used to determine the sintering temperature (700°C). Both optical microscopy and x-ray micotomography was used to determine the average pore size (540-680μm) of each scaffold. Cytocompatibility of each scaffold was conducted using murine mesenchymal stem cells.
骨科用cao - na20 - sio2 /TiO2玻璃陶瓷支架的生物相容性研究
本工作旨在确定以tio2取代SiO2在0.62SiO2- na20 -0.24 cao基玻璃陶瓷支架中的效果。采用高温x射线衍射(HT-XRD)测定烧结温度(700℃)。使用光学显微镜和x射线显微断层扫描测定每个支架的平均孔径(540-680μm)。采用小鼠间充质干细胞对各支架进行细胞相容性研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信