{"title":"Power Consumption Model of a Circulating Wet Runner Pump","authors":"B. Meier, M. Oettmeier, J. Fiedler, T. Bertram","doi":"10.1109/CCTA.2018.8511571","DOIUrl":null,"url":null,"abstract":"In this paper the power consumption model of a circulating wet runner pump is presented. Such a model provides several advantages since it can be used for example to detect issues during operation of the pump. For instance, dry running which might damage the bearings of the pump can be detected based on deviations between the measured power and the power predicted by the model. Furthermore, based on the power model the volume flow which passes the pump can be determined without a volume flow sensor and thus save costs. As the overall power consumption of the pump is influenced by different components such as electrical and friction losses, models of the individual components which have an influence on the power consumption are presented. Then, the components are combined to one overall power consumption model and the model parameters are identified by measurements. Finally, the model is validated by comparison of the dynamic behaviour of the model with the actual measured power consumption.","PeriodicalId":358360,"journal":{"name":"2018 IEEE Conference on Control Technology and Applications (CCTA)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Conference on Control Technology and Applications (CCTA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCTA.2018.8511571","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In this paper the power consumption model of a circulating wet runner pump is presented. Such a model provides several advantages since it can be used for example to detect issues during operation of the pump. For instance, dry running which might damage the bearings of the pump can be detected based on deviations between the measured power and the power predicted by the model. Furthermore, based on the power model the volume flow which passes the pump can be determined without a volume flow sensor and thus save costs. As the overall power consumption of the pump is influenced by different components such as electrical and friction losses, models of the individual components which have an influence on the power consumption are presented. Then, the components are combined to one overall power consumption model and the model parameters are identified by measurements. Finally, the model is validated by comparison of the dynamic behaviour of the model with the actual measured power consumption.