No clinical difference at mid-term follow-up between TiN-coated versus uncoated cemented mobile-bearing total knee arthroplasty: a matched cohort study.

IF 1.8 Q2 ORTHOPEDICS
SICOT-J Pub Date : 2023-01-01 DOI:10.1051/sicotj/2023001
Etienne Deroche, Cécile Batailler, Jobe Shatrov, Stanislas Gunst, Elvire Servien, Sébastien Lustig
{"title":"No clinical difference at mid-term follow-up between TiN-coated versus uncoated cemented mobile-bearing total knee arthroplasty: a matched cohort study.","authors":"Etienne Deroche,&nbsp;Cécile Batailler,&nbsp;Jobe Shatrov,&nbsp;Stanislas Gunst,&nbsp;Elvire Servien,&nbsp;Sébastien Lustig","doi":"10.1051/sicotj/2023001","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Nitride-based ceramic coating was introduced into surgical implants to improve hardness, reduce abrasion, and decrease the risk of metal-induced adverse reactions, especially for patients with suspected or identified metal hypersensitivity. The study aimed to evaluate the effectiveness and safety of a titanium nitride (TiN) coated prosthesis with a mobile bearing design.</p><p><strong>Methods: </strong>This was a retrospective matched-cohort study from a single center, comparing clinical outcomes between patients receiving either a TiN-coated versus an uncoated cobalt-chromium-molybdenum (CoCrMo) prostheses for primary total knee replacement. Seventeen patients received the TiN prosthesis between 2015 and 2019. These were matched 1:2 with patients receiving uncoated mobile-bearing knee prostheses with the same design manufacturer.</p><p><strong>Results: </strong>Fourteen patients in the TiN group had complete 5-year follow-up data and were compared with 34 patients from the CoCrMo group. The Knee Society Score was 170.6 ± 28.0 (Function subscore 83.7 ± 17.5 and Knee subscore 86.9 ± 13.8) in the TiN group and 180.7 ± 49.4 (Function subscore 87.5 ± 14.3 and Knee subscore 93.2 ± 9.6) in CoCrMo group, with no statistically significant difference (p = 0.19). One patient underwent a revision for instability requiring the removal of the implant in the TiN group and none in the CoCrMo group. The survival rates were 92.9% (CI95% 77.3-100.0) and 100.0% in the TiN group and CoCrMo group respectively (p = 1.0).</p><p><strong>Discussion: </strong>TiN-coated TKA with mobile bearing resulted in satisfactory clinical outcomes, and a low revision rate, and there was no complication related to the coated implant. The use of TiN-coated prostheses in case of confirmed or suspected metal allergy provides satisfactory short-term clinic outcomes.</p>","PeriodicalId":46378,"journal":{"name":"SICOT-J","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9910165/pdf/","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SICOT-J","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/sicotj/2023001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 1

Abstract

Introduction: Nitride-based ceramic coating was introduced into surgical implants to improve hardness, reduce abrasion, and decrease the risk of metal-induced adverse reactions, especially for patients with suspected or identified metal hypersensitivity. The study aimed to evaluate the effectiveness and safety of a titanium nitride (TiN) coated prosthesis with a mobile bearing design.

Methods: This was a retrospective matched-cohort study from a single center, comparing clinical outcomes between patients receiving either a TiN-coated versus an uncoated cobalt-chromium-molybdenum (CoCrMo) prostheses for primary total knee replacement. Seventeen patients received the TiN prosthesis between 2015 and 2019. These were matched 1:2 with patients receiving uncoated mobile-bearing knee prostheses with the same design manufacturer.

Results: Fourteen patients in the TiN group had complete 5-year follow-up data and were compared with 34 patients from the CoCrMo group. The Knee Society Score was 170.6 ± 28.0 (Function subscore 83.7 ± 17.5 and Knee subscore 86.9 ± 13.8) in the TiN group and 180.7 ± 49.4 (Function subscore 87.5 ± 14.3 and Knee subscore 93.2 ± 9.6) in CoCrMo group, with no statistically significant difference (p = 0.19). One patient underwent a revision for instability requiring the removal of the implant in the TiN group and none in the CoCrMo group. The survival rates were 92.9% (CI95% 77.3-100.0) and 100.0% in the TiN group and CoCrMo group respectively (p = 1.0).

Discussion: TiN-coated TKA with mobile bearing resulted in satisfactory clinical outcomes, and a low revision rate, and there was no complication related to the coated implant. The use of TiN-coated prostheses in case of confirmed or suspected metal allergy provides satisfactory short-term clinic outcomes.

Abstract Image

Abstract Image

Abstract Image

中期随访中,tin包覆与未包覆的骨水泥可移动全膝关节置换术无临床差异:一项匹配队列研究。
导论:氮基陶瓷涂层被引入到外科植入物中,以提高硬度,减少磨损,降低金属诱发不良反应的风险,特别是对于怀疑或确定金属过敏的患者。本研究旨在评估氮化钛(TiN)涂层具有移动轴承设计的假体的有效性和安全性。方法:这是一项来自单中心的回顾性匹配队列研究,比较接受tin涂层和未涂层钴铬钼(CoCrMo)假体进行原发性全膝关节置换术的患者的临床结果。2015年至2019年期间,17名患者接受了TiN假体。这些患者与接受相同设计制造商的无涂层可移动膝关节假体的患者的比例为1:2。结果:TiN组14例患者有完整的5年随访数据,与CoCrMo组34例患者相比。TiN组膝关节社会评分为170.6±28.0分(功能评分83.7±17.5分,膝关节评分86.9±13.8分),CoCrMo组膝关节社会评分为180.7±49.4分(功能评分87.5±14.3分,膝关节评分93.2±9.6分),差异无统计学意义(p = 0.19)。TiN组有1例患者因不稳定需要移除植入物而进行了翻修,而CoCrMo组没有患者。TiN组和CoCrMo组的生存率分别为92.9% (CI95% 77.3 ~ 100.0)和100.0% (p = 1.0)。讨论:锡包覆可移动承载TKA临床效果满意,修复率低,无与包覆种植体相关的并发症。在确认或怀疑金属过敏的情况下,使用锡涂层假体提供了令人满意的短期临床结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
SICOT-J
SICOT-J ORTHOPEDICS-
CiteScore
3.20
自引率
12.50%
发文量
44
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信