Magnetic temporal interference for noninvasive and focal brain stimulation.

IF 4 3区 医学 Q2 ENGINEERING, BIOMEDICAL
Adam Khalifa, Seyed Mahdi Abrishami, Mohsen Zaeimbashi, Alexander D Tang, Brian Coughlin, Jennifer Rodger, Nian X Sun, Sydney S Cash
{"title":"Magnetic temporal interference for noninvasive and focal brain stimulation.","authors":"Adam Khalifa,&nbsp;Seyed Mahdi Abrishami,&nbsp;Mohsen Zaeimbashi,&nbsp;Alexander D Tang,&nbsp;Brian Coughlin,&nbsp;Jennifer Rodger,&nbsp;Nian X Sun,&nbsp;Sydney S Cash","doi":"10.1088/1741-2552/acb015","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective</i>. Noninvasive focal stimulation of deep brain regions has been a major goal for neuroscience and neuromodulation in the past three decades. Transcranial magnetic stimulation (TMS), for instance, cannot target deep regions in the brain without activating the overlying tissues and has poor spatial resolution. In this manuscript, we propose a new concept that relies on the temporal interference (TI) of two high-frequency magnetic fields generated by two electromagnetic solenoids.<i>Approach</i>. To illustrate the concept, custom solenoids were fabricated and optimized to generate temporal interfering electric fields for rodent brain stimulation. C-Fos expression was used to track neuronal activation.<i>Main result</i>. C-Fos expression was not present in regions impacted by only one high-frequency magnetic field indicating ineffective recruitment of neural activity in non-target regions. In contrast, regions impacted by two fields that interfere to create a low-frequency envelope display a strong increase in c-Fos expression.<i>Significance</i>. Therefore, this magnetic temporal interference solenoid-based system provides a framework to perform further stimulation studies that would investigate the advantages it could bring over conventional TMS systems.</p>","PeriodicalId":16753,"journal":{"name":"Journal of neural engineering","volume":"20 1","pages":""},"PeriodicalIF":4.0000,"publicationDate":"2023-01-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neural engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1741-2552/acb015","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 6

Abstract

Objective. Noninvasive focal stimulation of deep brain regions has been a major goal for neuroscience and neuromodulation in the past three decades. Transcranial magnetic stimulation (TMS), for instance, cannot target deep regions in the brain without activating the overlying tissues and has poor spatial resolution. In this manuscript, we propose a new concept that relies on the temporal interference (TI) of two high-frequency magnetic fields generated by two electromagnetic solenoids.Approach. To illustrate the concept, custom solenoids were fabricated and optimized to generate temporal interfering electric fields for rodent brain stimulation. C-Fos expression was used to track neuronal activation.Main result. C-Fos expression was not present in regions impacted by only one high-frequency magnetic field indicating ineffective recruitment of neural activity in non-target regions. In contrast, regions impacted by two fields that interfere to create a low-frequency envelope display a strong increase in c-Fos expression.Significance. Therefore, this magnetic temporal interference solenoid-based system provides a framework to perform further stimulation studies that would investigate the advantages it could bring over conventional TMS systems.

磁颞干扰用于无创和局灶性脑刺激。
目标。在过去的三十年里,对脑深部区域进行无创的局部刺激一直是神经科学和神经调节的主要目标。例如,经颅磁刺激(TMS)不能在不激活覆盖的组织的情况下瞄准大脑的深层区域,而且空间分辨率很差。在本文中,我们提出了一个依赖于两个电磁螺线管产生的两个高频磁场的时间干扰(TI)的新概念。为了说明这一概念,我们制作并优化了定制的螺线管,以产生用于刺激啮齿动物大脑的时间干扰电场。C-Fos表达用于跟踪神经元激活。主要的结果。C-Fos表达不存在于仅受一个高频磁场影响的区域,这表明非目标区域的神经活动募集无效。相比之下,受两个电场干扰形成低频包络的区域显示出c-Fos表达的强烈增加。因此,这种基于磁时间干扰螺杆管的系统提供了一个框架,可以进行进一步的刺激研究,以研究它与传统TMS系统相比的优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of neural engineering
Journal of neural engineering 工程技术-工程:生物医学
CiteScore
7.80
自引率
12.50%
发文量
319
审稿时长
4.2 months
期刊介绍: The goal of Journal of Neural Engineering (JNE) is to act as a forum for the interdisciplinary field of neural engineering where neuroscientists, neurobiologists and engineers can publish their work in one periodical that bridges the gap between neuroscience and engineering. The journal publishes articles in the field of neural engineering at the molecular, cellular and systems levels. The scope of the journal encompasses experimental, computational, theoretical, clinical and applied aspects of: Innovative neurotechnology; Brain-machine (computer) interface; Neural interfacing; Bioelectronic medicines; Neuromodulation; Neural prostheses; Neural control; Neuro-rehabilitation; Neurorobotics; Optical neural engineering; Neural circuits: artificial & biological; Neuromorphic engineering; Neural tissue regeneration; Neural signal processing; Theoretical and computational neuroscience; Systems neuroscience; Translational neuroscience; Neuroimaging.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书