The Role of Wearable Technology in Measuring and Supporting Patient Outcomes Following Total Joint Replacement: Review of the Literature.

Gregory Iovanel, David Ayers, Hua Zheng
{"title":"The Role of Wearable Technology in Measuring and Supporting Patient Outcomes Following Total Joint Replacement: Review of the Literature.","authors":"Gregory Iovanel,&nbsp;David Ayers,&nbsp;Hua Zheng","doi":"10.2196/39396","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The incidence rate of total joint replacement (TJR) continues to increase due to the aging population and the surgery that is very successful in providing pain relief to and improving function among patients with advanced knee or hip arthritis. Improving patient outcomes and patient satisfaction after TJR remain important goals. Wearable technologies provide a novel way to capture patient function and activity data and supplement clinical measures and patient-reported outcome measures in order to better understand patient outcomes after TJR.</p><p><strong>Objective: </strong>We examined the current literature to evaluate the potential role of wearable devices and compare them with existing methods for monitoring and improving patient rehabilitation and outcomes following TJR.</p><p><strong>Methods: </strong>We performed a literature search by using the research databases supported by the University of Massachusetts Chan Medical School's Lamar Soutter Library, including PubMed and Scopus, supplemented with the Google Scholar search engine. A specific search strategy was used to identify articles discussing the use of wearable devices in measuring and affecting postoperative outcomes of patients who have undergone TJR. Selected papers were organized into a spreadsheet and categorized for our qualitative literature review to assess how wearable data correlated with clinical measures and patient-reported outcome measures.</p><p><strong>Results: </strong>A total of 9 papers were selected. The literature showed the impact of wearable devices on evaluating and improving postoperative functional outcomes. Wearable-collected data could be used to predict postoperative clinical measures, such as range of motion and Timed Up and Go times. When predicting patient-reported outcomes, specifically Hip Disability and Osteoarthritis Outcome Scores/Knee Injury and Osteoarthritis Outcome Scores and Veterans RAND 12-Item Health Survey scores, strong associations were found between changes in sensor-collected data and changes in patient-reported outcomes over time. Further, the step counts of patients who received feedback from a wearable improved over time when compared to those of patients who did not receive feedback.</p><p><strong>Conclusions: </strong>These findings suggest that wearable technology has the potential to remotely measure and improve postoperative orthopedic patient outcomes. We anticipate that this review will facilitate further investigation into whether wearable devices are viable tools for guiding the clinical management of TJR rehabilitation.</p>","PeriodicalId":73557,"journal":{"name":"JMIR perioperative medicine","volume":"6 ","pages":"e39396"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9880809/pdf/","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JMIR perioperative medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2196/39396","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Background: The incidence rate of total joint replacement (TJR) continues to increase due to the aging population and the surgery that is very successful in providing pain relief to and improving function among patients with advanced knee or hip arthritis. Improving patient outcomes and patient satisfaction after TJR remain important goals. Wearable technologies provide a novel way to capture patient function and activity data and supplement clinical measures and patient-reported outcome measures in order to better understand patient outcomes after TJR.

Objective: We examined the current literature to evaluate the potential role of wearable devices and compare them with existing methods for monitoring and improving patient rehabilitation and outcomes following TJR.

Methods: We performed a literature search by using the research databases supported by the University of Massachusetts Chan Medical School's Lamar Soutter Library, including PubMed and Scopus, supplemented with the Google Scholar search engine. A specific search strategy was used to identify articles discussing the use of wearable devices in measuring and affecting postoperative outcomes of patients who have undergone TJR. Selected papers were organized into a spreadsheet and categorized for our qualitative literature review to assess how wearable data correlated with clinical measures and patient-reported outcome measures.

Results: A total of 9 papers were selected. The literature showed the impact of wearable devices on evaluating and improving postoperative functional outcomes. Wearable-collected data could be used to predict postoperative clinical measures, such as range of motion and Timed Up and Go times. When predicting patient-reported outcomes, specifically Hip Disability and Osteoarthritis Outcome Scores/Knee Injury and Osteoarthritis Outcome Scores and Veterans RAND 12-Item Health Survey scores, strong associations were found between changes in sensor-collected data and changes in patient-reported outcomes over time. Further, the step counts of patients who received feedback from a wearable improved over time when compared to those of patients who did not receive feedback.

Conclusions: These findings suggest that wearable technology has the potential to remotely measure and improve postoperative orthopedic patient outcomes. We anticipate that this review will facilitate further investigation into whether wearable devices are viable tools for guiding the clinical management of TJR rehabilitation.

可穿戴技术在测量和支持全关节置换术后患者预后中的作用:文献综述。
背景:由于人口老龄化和手术在缓解晚期膝关节或髋关节关节炎患者疼痛和改善功能方面非常成功,全关节置换术(TJR)的发病率持续增加。改善TJR后的患者预后和患者满意度仍然是重要的目标。可穿戴技术提供了一种捕捉患者功能和活动数据的新方法,并补充了临床测量和患者报告的结果测量,以便更好地了解患者TJR后的结果。目的:我们研究了现有的文献,以评估可穿戴设备的潜在作用,并将其与现有的监测和改善TJR患者康复和预后的方法进行比较。方法:利用麻省大学陈医学院Lamar Soutter图书馆支持的研究数据库,包括PubMed和Scopus,并辅以Google Scholar搜索引擎进行文献检索。使用特定的搜索策略来识别讨论可穿戴设备在测量和影响TJR患者术后结果中的使用的文章。选定的论文被组织成一个电子表格,并归类为我们的定性文献综述,以评估可穿戴数据与临床测量和患者报告的结果测量的相关性。结果:共入选9篇论文。文献显示了可穿戴设备对评估和改善术后功能结果的影响。可穿戴设备收集的数据可用于预测术后的临床指标,如活动范围和定时起跳时间。当预测患者报告的结果时,特别是髋关节残疾和骨关节炎结果评分/膝关节损伤和骨关节炎结果评分和退伍军人RAND 12项健康调查评分时,发现传感器收集的数据变化与患者报告的结果变化之间存在很强的相关性。此外,与没有收到反馈的患者相比,接受可穿戴设备反馈的患者的步数随着时间的推移有所改善。结论:这些发现表明,可穿戴技术具有远程测量和改善骨科术后患者预后的潜力。我们期望这篇综述将有助于进一步研究可穿戴设备是否是指导TJR康复临床管理的可行工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
0
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信