An audit of patient radiation doses in interventional radiology at a South African hospital.

IF 0.7 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Oneile Slave, Nasreen Mahomed
{"title":"An audit of patient radiation doses in interventional radiology at a South African hospital.","authors":"Oneile Slave,&nbsp;Nasreen Mahomed","doi":"10.4102/sajr.v27i1.2559","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Interventional radiology (IR) is becoming more relevant in patient care and is associated with increased patient radiation exposure and radiation-induced adverse effects. Diagnostic reference levels (DRLs) are crucial for radiation control. There is a paucity of published DRLs for IR in South Africa and sub-Saharan Africa.</p><p><strong>Objectives: </strong>This study aimed to determine local DRLs for fluoroscopically-guided IR procedures and compare the achieved DRLs with published local and international DRLs.</p><p><strong>Method: </strong>Retrospective, descriptive, single-centre study. Kerma air product (KAP), reference point air kerma (K<sub>a,r</sub>) and fluoroscopy time (FT) were collected for patients (12 years and older) who underwent IR procedures at a university hospital from 01 January 2019 to 31 December 2019. The 75th percentile of the distribution of each dose parameter (KAP, K<sub>a,r</sub> and FT) per procedure was calculated and taken as the local diagnostic reference levels (LDRL). The established LDRLs were compared to published DRLs.</p><p><strong>Results: </strong>A total of 564 cases were evaluated. The 13 most frequent procedures (with 15 or more cases) represented 86.1% (487/564). Percutaneous transhepatic biliary drainage was the most common procedure (<i>n</i> = 146, 25.9%). Diagnostic cerebral angiogram DRLs exceeded the published DRL data ranges for all parameters (DRL 209.3), and interventional cerebral angiogram exceeded published ranges (DRL 275). Uterine artery embolisation (UAE) exceeded these ranges for KAP and K<sub>a,r</sub>. (KAP-954.9 Gy/cm<sup>2</sup>, K<sub>a,r</sub>-2640.8 mGy).</p><p><strong>Conclusion: </strong>The LDRLs for diagnostic cerebral angiogram, interventional cerebral angiogram and UAE exceeded published international DRL ranges. These procedures require radiation optimisation as recommended by the International Commission on Radiological Protection (ICRP).</p><p><strong>Contribution: </strong>In addition to informing radiation protection practices at the level of the institution, the established LDRLs contribute towards Regional and National DRLs.</p>","PeriodicalId":43442,"journal":{"name":"SA Journal of Radiology","volume":"27 1","pages":"2559"},"PeriodicalIF":0.7000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9900283/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SA Journal of Radiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4102/sajr.v27i1.2559","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Interventional radiology (IR) is becoming more relevant in patient care and is associated with increased patient radiation exposure and radiation-induced adverse effects. Diagnostic reference levels (DRLs) are crucial for radiation control. There is a paucity of published DRLs for IR in South Africa and sub-Saharan Africa.

Objectives: This study aimed to determine local DRLs for fluoroscopically-guided IR procedures and compare the achieved DRLs with published local and international DRLs.

Method: Retrospective, descriptive, single-centre study. Kerma air product (KAP), reference point air kerma (Ka,r) and fluoroscopy time (FT) were collected for patients (12 years and older) who underwent IR procedures at a university hospital from 01 January 2019 to 31 December 2019. The 75th percentile of the distribution of each dose parameter (KAP, Ka,r and FT) per procedure was calculated and taken as the local diagnostic reference levels (LDRL). The established LDRLs were compared to published DRLs.

Results: A total of 564 cases were evaluated. The 13 most frequent procedures (with 15 or more cases) represented 86.1% (487/564). Percutaneous transhepatic biliary drainage was the most common procedure (n = 146, 25.9%). Diagnostic cerebral angiogram DRLs exceeded the published DRL data ranges for all parameters (DRL 209.3), and interventional cerebral angiogram exceeded published ranges (DRL 275). Uterine artery embolisation (UAE) exceeded these ranges for KAP and Ka,r. (KAP-954.9 Gy/cm2, Ka,r-2640.8 mGy).

Conclusion: The LDRLs for diagnostic cerebral angiogram, interventional cerebral angiogram and UAE exceeded published international DRL ranges. These procedures require radiation optimisation as recommended by the International Commission on Radiological Protection (ICRP).

Contribution: In addition to informing radiation protection practices at the level of the institution, the established LDRLs contribute towards Regional and National DRLs.

Abstract Image

对南非一家医院介入放射学病人辐射剂量的审计。
背景:介入放射学(IR)在患者护理中变得越来越重要,并且与患者辐射暴露和辐射诱发的不良反应增加有关。诊断参考水平(drl)对辐射控制至关重要。在南非和撒哈拉以南非洲,关于IR的已发表的drl很少。目的:本研究旨在确定透视引导下IR手术的局部drl,并将已实现的drl与已公布的本地和国际drl进行比较。方法:回顾性、描述性、单中心研究。收集2019年1月1日至2019年12月31日在某大学医院接受IR手术的患者(12岁及以上)的克尔玛空气产品(KAP)、参考点克尔玛空气(Ka,r)和透视时间(FT)。计算每次手术各剂量参数(KAP、Ka、r和FT)分布的第75百分位数,作为局部诊断参考水平(LDRL)。将已建立的ldrl与已发表的ldrl进行比较。结果:共评估564例。13种最常见的手术(15例或以上)占86.1%(487/564)。经皮经肝胆道引流是最常见的手术(n = 146, 25.9%)。诊断性脑血管造影的DRL在所有参数上都超过了公布的DRL数据范围(DRL 209.3),介入性脑血管造影超出了公布的范围(DRL 275)。子宫动脉栓塞(UAE)超过了KAP和Ka,r的范围。(KAP-954.9 Gy/cm2, Ka,r-2640.8 mGy)。结论:诊断性脑血管造影、介入性脑血管造影和UAE的ldrl均超过国际公布的DRL范围。这些程序需要按照国际放射防护委员会(ICRP)的建议进行辐射优化。贡献:除了为机构一级的辐射防护实践提供信息外,已建立的最低限度限值还对区域和国家最低限度限值作出贡献。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
SA Journal of Radiology
SA Journal of Radiology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.20
自引率
11.10%
发文量
35
审稿时长
16 weeks
期刊介绍: The SA Journal of Radiology is the official journal of the Radiological Society of South Africa and the Professional Association of Radiologists in South Africa and Namibia. The SA Journal of Radiology is a general diagnostic radiological journal which carries original research and review articles, pictorial essays, case reports, letters, editorials, radiological practice and other radiological articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信