{"title":"Comparison of Hybrid Versus Synthetic Mesh in Robotic Rives-Stoppa Ventral Hernia Repair.","authors":"Omar Yusef Kudsi, Georges Kaoukabani, Naseem Bou-Ayash, Fahri Gokcal","doi":"10.4293/JSLS.2022.00071","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>To estimate the average treatment effect on the treated (ATT) and to assess the clinical outcomes in two different types of mesh in robotic Rives-Stoppa (rRS) ventral hernia repair (VHR).</p><p><strong>Methods: </strong>A retrospective analysis of a robotic VHR database between February 1, 2013 and May 31, 2022. Patients who underwent a rRS VHR were included in this study and separated into two groups depending on the mesh used: Synecor<sup>TM</sup> Preperitoneal Biomaterial (Synecor<sup>TM</sup> Pre) and Bard™ Soft. Through propensity score and inverse-probability-treatment-weighting, the ATT was estimated for two scenarios; the first with the treated target having used the Synecor<sup>TM</sup> Pre, the second having used the Bard™ Soft mesh. Adjusted linear regression models, including lingering imbalanced variables, were used for both the primary outcome of the Comprehensive Complication Index (CCI®), and the secondary outcome of the hospital cost.</p><p><strong>Results: </strong>A total of 186 patients who underwent rRS were separated into the two groups (Synecor<sup>TM</sup> Pre mesh, n = 85; Bard™ Soft mesh, n = 101). Adjusted linear regression models for the CCI showed no statistical difference between both groups (p > 0.05), whereas ATT on hospital cost was significantly higher (<i>p</i> < 0.001) in the Synecor<sup>TM</sup> Pre group in both scenarios [(95% confidence interval) = 3882 (2352, 5413) and -5185 (-8213, -2157), respectively].</p><p><strong>Conclusion: </strong>Both mesh materials provided excellent outcomes with no difference in complications or recurrence rates. However, hospital cost was found to be higher in the hybrid mesh group. Long-term follow-up is needed to fully assess the performance of both mesh types in rRS.</p>","PeriodicalId":17679,"journal":{"name":"JSLS : Journal of the Society of Laparoendoscopic Surgeons","volume":"26 4","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/4d/cc/e2022.00071.PMC9840217.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JSLS : Journal of the Society of Laparoendoscopic Surgeons","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4293/JSLS.2022.00071","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
Background and objectives: To estimate the average treatment effect on the treated (ATT) and to assess the clinical outcomes in two different types of mesh in robotic Rives-Stoppa (rRS) ventral hernia repair (VHR).
Methods: A retrospective analysis of a robotic VHR database between February 1, 2013 and May 31, 2022. Patients who underwent a rRS VHR were included in this study and separated into two groups depending on the mesh used: SynecorTM Preperitoneal Biomaterial (SynecorTM Pre) and Bard™ Soft. Through propensity score and inverse-probability-treatment-weighting, the ATT was estimated for two scenarios; the first with the treated target having used the SynecorTM Pre, the second having used the Bard™ Soft mesh. Adjusted linear regression models, including lingering imbalanced variables, were used for both the primary outcome of the Comprehensive Complication Index (CCI®), and the secondary outcome of the hospital cost.
Results: A total of 186 patients who underwent rRS were separated into the two groups (SynecorTM Pre mesh, n = 85; Bard™ Soft mesh, n = 101). Adjusted linear regression models for the CCI showed no statistical difference between both groups (p > 0.05), whereas ATT on hospital cost was significantly higher (p < 0.001) in the SynecorTM Pre group in both scenarios [(95% confidence interval) = 3882 (2352, 5413) and -5185 (-8213, -2157), respectively].
Conclusion: Both mesh materials provided excellent outcomes with no difference in complications or recurrence rates. However, hospital cost was found to be higher in the hybrid mesh group. Long-term follow-up is needed to fully assess the performance of both mesh types in rRS.
期刊介绍:
JSLS, Journal of the Society of Laparoscopic & Robotic Surgeons publishes original scientific articles on basic science and technical topics in all the fields involved with laparoscopic, robotic, and minimally invasive surgery. CRSLS, MIS Case Reports from SLS is dedicated to the publication of Case Reports in the field of minimally invasive surgery. The journals seek to advance our understandings and practice of minimally invasive, image-guided surgery by providing a forum for all relevant disciplines and by promoting the exchange of information and ideas across specialties.