Comparison of microvascular flow imaging and contrast-enhanced ultrasound for blood flow analysis of cervical lymph node lesions.

IF 2.1 4区 医学 Q3 HEMATOLOGY
Tianqi Wang, Mingda Xu, Changyu Xu, Yuqing Wu, Xiaoqiu Dong
{"title":"Comparison of microvascular flow imaging and contrast-enhanced ultrasound for blood flow analysis of cervical lymph node lesions.","authors":"Tianqi Wang, Mingda Xu, Changyu Xu, Yuqing Wu, Xiaoqiu Dong","doi":"10.3233/CH-231860","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare the diagnostic value of microvascular flow imaging (MVFI) with that of contrast-enhanced ultrasound (CEUS) for the analysis of blood flow in benign and malignant cervical lymph nodes.</p><p><strong>Material and methods: </strong>As a prospective study, 95 cervical enlarged lymph nodes (43 benign and 52 malignant) were observed in 95 patients using conventional ultrasonography (including gray and Color Doppler Flow Imaging), CEUS, and MVFI. Two researchers evaluated vascular parameters of MVFI (vascular distribution, internal vascular features, vascular index) and CEUS (enhancement mode, enhancement type) and compared the diagnostic effects of MVFI and CEUS.All results were compared with pathological findings.</p><p><strong>Results: </strong>There were significant differences in the vascular distribution and internal vascular features of benign and malignant lymph nodes on MVFI (P < 0.05). The vascular distribution of benign lymph nodes was mainly of the central and avascular types, the internal blood vessels were mostly normal, the vascular distribution of malignant lymph nodes was mainly mixed, the internal vessels were mainly tortuous and displaced. The optimal cut-off value of the benign and malignant lymph node vascular index (VI) was 15.55%, and the area under the receiver operating characteristic curve (AUC) of the VI was 0.876. There were also significant differences in the enhancement mode and types of benign and malignant lymph nodes in CEUS (P < 0.05). The benign lymph nodes showed centrifugal perfusion, and the enhancement types were mostly type I and type II. Most malignant lymph nodes showed centripetal or mixed perfusion, and the enhancement types were usually type III and type IV. The accuracy, sensitivity, and specificity of CEUS in the diagnosis of lymph node lesions were 84.2%, 84.6% and 83.7%, respectively, and the AUC was 0.845. The accuracy, sensitivity, and specificity of MVFI in the diagnosis of lymph node lesions were 85.3%, 84.6%, and 86.0%, respectively, and the AUC was 0.886.</p><p><strong>Conclusion: </strong>Both CEUS and MVFI are valuable in differentiating benign and malignant lesions of lymph nodes and have a similar diagnostic performance; however, MVFI is less invasive and simpler than CEUS. Therefore it is preferred for auxiliary examination of enlarged lymph nodes that are difficult to diagnose by conventional ultrasound.</p>","PeriodicalId":10425,"journal":{"name":"Clinical hemorheology and microcirculation","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical hemorheology and microcirculation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3233/CH-231860","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To compare the diagnostic value of microvascular flow imaging (MVFI) with that of contrast-enhanced ultrasound (CEUS) for the analysis of blood flow in benign and malignant cervical lymph nodes.

Material and methods: As a prospective study, 95 cervical enlarged lymph nodes (43 benign and 52 malignant) were observed in 95 patients using conventional ultrasonography (including gray and Color Doppler Flow Imaging), CEUS, and MVFI. Two researchers evaluated vascular parameters of MVFI (vascular distribution, internal vascular features, vascular index) and CEUS (enhancement mode, enhancement type) and compared the diagnostic effects of MVFI and CEUS.All results were compared with pathological findings.

Results: There were significant differences in the vascular distribution and internal vascular features of benign and malignant lymph nodes on MVFI (P < 0.05). The vascular distribution of benign lymph nodes was mainly of the central and avascular types, the internal blood vessels were mostly normal, the vascular distribution of malignant lymph nodes was mainly mixed, the internal vessels were mainly tortuous and displaced. The optimal cut-off value of the benign and malignant lymph node vascular index (VI) was 15.55%, and the area under the receiver operating characteristic curve (AUC) of the VI was 0.876. There were also significant differences in the enhancement mode and types of benign and malignant lymph nodes in CEUS (P < 0.05). The benign lymph nodes showed centrifugal perfusion, and the enhancement types were mostly type I and type II. Most malignant lymph nodes showed centripetal or mixed perfusion, and the enhancement types were usually type III and type IV. The accuracy, sensitivity, and specificity of CEUS in the diagnosis of lymph node lesions were 84.2%, 84.6% and 83.7%, respectively, and the AUC was 0.845. The accuracy, sensitivity, and specificity of MVFI in the diagnosis of lymph node lesions were 85.3%, 84.6%, and 86.0%, respectively, and the AUC was 0.886.

Conclusion: Both CEUS and MVFI are valuable in differentiating benign and malignant lesions of lymph nodes and have a similar diagnostic performance; however, MVFI is less invasive and simpler than CEUS. Therefore it is preferred for auxiliary examination of enlarged lymph nodes that are difficult to diagnose by conventional ultrasound.

微血管血流成像与对比增强超声在宫颈淋巴结病变血流分析中的比较。
目的比较微血管血流成像(MVFI)与对比增强超声(CEUS)对良性和恶性宫颈淋巴结血流分析的诊断价值:作为一项前瞻性研究,研究人员使用传统超声造影(包括灰阶和彩色多普勒血流成像)、CEUS和MVFI对95名患者的95个宫颈肿大淋巴结(43个良性和52个恶性)进行了观察。两名研究人员评估了 MVFI(血管分布、内部血管特征、血管指数)和 CEUS(增强模式、增强类型)的血管参数,并比较了 MVFI 和 CEUS 的诊断效果:结果:MVFI显示的良性和恶性淋巴结的血管分布和内部血管特征有明显差异(P 结论:CEUS和MVFI对淋巴结的诊断均有重要意义:CEUS 和 MVFI 对淋巴结良恶性病变的鉴别均有价值,诊断效果相似;但 MVFI 比 CEUS 侵袭性更小,更简单。因此,对于常规超声难以诊断的肿大淋巴结,MVFI 是首选的辅助检查方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.30
自引率
33.30%
发文量
170
期刊介绍: Clinical Hemorheology and Microcirculation, a peer-reviewed international scientific journal, serves as an aid to understanding the flow properties of blood and the relationship to normal and abnormal physiology. The rapidly expanding science of hemorheology concerns blood, its components and the blood vessels with which blood interacts. It includes perihemorheology, i.e., the rheology of fluid and structures in the perivascular and interstitial spaces as well as the lymphatic system. The clinical aspects include pathogenesis, symptomatology and diagnostic methods, and the fields of prophylaxis and therapy in all branches of medicine and surgery, pharmacology and drug research. The endeavour of the Editors-in-Chief and publishers of Clinical Hemorheology and Microcirculation is to bring together contributions from those working in various fields related to blood flow all over the world. The editors of Clinical Hemorheology and Microcirculation are from those countries in Europe, Asia, Australia and America where appreciable work in clinical hemorheology and microcirculation is being carried out. Each editor takes responsibility to decide on the acceptance of a manuscript. He is required to have the manuscript appraised by two referees and may be one of them himself. The executive editorial office, to which the manuscripts have been submitted, is responsible for rapid handling of the reviewing process. Clinical Hemorheology and Microcirculation accepts original papers, brief communications, mini-reports and letters to the Editors-in-Chief. Review articles, providing general views and new insights into related subjects, are regularly invited by the Editors-in-Chief. Proceedings of international and national conferences on clinical hemorheology (in original form or as abstracts) complete the range of editorial features.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信