Comparison of three orthodontic bonding systems in white spot lesion development: a randomized clinical trial.

IF 3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Ola G Abu Horan, Susan N Al-Khateeb
{"title":"Comparison of three orthodontic bonding systems in white spot lesion development: a randomized clinical trial.","authors":"Ola G Abu Horan,&nbsp;Susan N Al-Khateeb","doi":"10.2319/111422-781.1","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To compare the development of white spot lesions (WSLs) during fixed orthodontic therapy among a conventional three-step bonding system, a self-etching primer bonding system, and a one-step adhesive bonding system.</p><p><strong>Materials and methods: </strong>Seventy-five patients were randomly allocated into three groups (group 1, conventional bonding system, n = 25; group 2, self-etch primer, n = 25; group 3, primer mixed with adhesive composite, n = 25). Quantitative light-induced fluorescence (QLF) was used to assess WSL parameters. Images were captured and then analyzed before treatment and at 2 months and 4 months after bond up. Lesion area (pixels), mean fluorescence loss (ΔF), and the number of newly developed WSLs were compared within and among the three groups. The significance level was P ≤ .05.</p><p><strong>Results: </strong>The mean increase in lesion area was 31.3 ± 2.8 pixels, 38.4 ± 4.3 pixels, and 119.5 ± 5.3 pixels for groups 1, 2, and 3, respectively (P ≤ .001). For ΔF, the loss was 3.3% ± 0.3%, 4.4% ± 0.2%, and 6.6% ± 0.2% for groups 1, 2, and 3, respectively. These changes were significantly different (P ≤ .01 to P ≤ .001). The incidence of newly developed lesions was 9.5 WSLs in group 1, 10 WSLs in group 2, and 15.9 WSLs in group 3.</p><p><strong>Conclusions: </strong>The lack of primer contributed to the development of a larger number of and more severe WSLs.</p>","PeriodicalId":50790,"journal":{"name":"Angle Orthodontist","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10575644/pdf/i1945-7103-93-5-531.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Angle Orthodontist","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2319/111422-781.1","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To compare the development of white spot lesions (WSLs) during fixed orthodontic therapy among a conventional three-step bonding system, a self-etching primer bonding system, and a one-step adhesive bonding system.

Materials and methods: Seventy-five patients were randomly allocated into three groups (group 1, conventional bonding system, n = 25; group 2, self-etch primer, n = 25; group 3, primer mixed with adhesive composite, n = 25). Quantitative light-induced fluorescence (QLF) was used to assess WSL parameters. Images were captured and then analyzed before treatment and at 2 months and 4 months after bond up. Lesion area (pixels), mean fluorescence loss (ΔF), and the number of newly developed WSLs were compared within and among the three groups. The significance level was P ≤ .05.

Results: The mean increase in lesion area was 31.3 ± 2.8 pixels, 38.4 ± 4.3 pixels, and 119.5 ± 5.3 pixels for groups 1, 2, and 3, respectively (P ≤ .001). For ΔF, the loss was 3.3% ± 0.3%, 4.4% ± 0.2%, and 6.6% ± 0.2% for groups 1, 2, and 3, respectively. These changes were significantly different (P ≤ .01 to P ≤ .001). The incidence of newly developed lesions was 9.5 WSLs in group 1, 10 WSLs in group 2, and 15.9 WSLs in group 3.

Conclusions: The lack of primer contributed to the development of a larger number of and more severe WSLs.

三种正畸粘接系统在白斑病变发展中的比较:一项随机临床试验。
目的:比较传统三步粘接系统、自蚀刻底漆粘接系统和一步粘接系统在固定正畸治疗过程中白斑病变(WSL)的发展情况。材料和方法:75例患者被随机分为三组(第一组,常规粘接系统,n=25;第二组,自蚀刻底漆,n=25,第三组,底漆与粘合剂复合物混合,n=25)。定量光诱导荧光(QLF)用于评估WSL参数。在治疗前以及结合后2个月和4个月采集图像并进行分析。比较三组内和三组间的病变面积(像素)、平均荧光损失(ΔF)和新发展的WSL数量。显著性水平为P≤.05。结果:第1、2和3组病变面积的平均增加分别为31.3±2.8像素、38.4±4.3像素和119.5±5.3像素(P≤.001)。ΔF的损失分别为3.3%±0.3%、4.4%±0.2%和6.6%±0.2%。这些变化有显著差异(P≤.01至P≤.001)。新发病变的发生率在第1组为9.5个WSL,第2组为10个,第3组为15.9个WSL。结论:缺乏引物导致了更多、更严重的WSL的发生。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Angle Orthodontist
Angle Orthodontist 医学-牙科与口腔外科
CiteScore
6.40
自引率
5.90%
发文量
95
审稿时长
3 months
期刊介绍: The Angle Orthodontist is the official publication of the Edward H. Angle Society of Orthodontists and is published bimonthly in January, March, May, July, September and November by The EH Angle Education and Research Foundation Inc. The Angle Orthodontist is the only major journal in orthodontics with a non-commercial, non-profit publisher -- The E. H. Angle Education and Research Foundation. We value our freedom to operate exclusively in the best interests of our readers and authors. Our website www.angle.org is completely free and open to all visitors.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信