Daria Chmielewska, Maciej Cebula, Rafał Gnat, Magdalena Rudek-Zeprzałka, Katarzyna Gruszczyńska, Jan Baron, Agnieszka Opala-Berdzik
{"title":"Reliability of inter-recti distance measurement on ultrasound images captured by novice examiners.","authors":"Daria Chmielewska, Maciej Cebula, Rafał Gnat, Magdalena Rudek-Zeprzałka, Katarzyna Gruszczyńska, Jan Baron, Agnieszka Opala-Berdzik","doi":"10.1080/09593985.2023.2255897","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>With the increased interest in inter-recti distance measurement using ultrasound imaging in physiotherapy, there is a question of measurement reliability, and the importance of the examiner's experience.</p><p><strong>Purpose: </strong>The study aimed to investigate the reliability of inter-recti distance measurement in a DICOM viewer software by an experienced radiologist. For the measurement, the radiologist used linea alba images captured by two physiotherapists who were novice examiners.</p><p><strong>Methods: </strong>Ultrasound images were acquired by two novice examiners on repeated occasions 7 days apart (sessions A and B) in 28 nulliparous women at supraumbilical, umbilical, and infraumbilical locations along linea alba.</p><p><strong>Results: </strong>Excellent intra-examiner reliability of inter-recti distance measurements was shown at the supraumbilical and umbilical levels (ICC<sub>2,k</sub> = 0.941-0.983) with minimal detectable change (MDC<sub>95</sub>) ranging from 1.31 mm to 2.29 mm. Infraumbilical measurements had good to excellent reliability (ICC<sub>2,k</sub> = 0.894-0.972) with MDC<sub>95</sub> ranging from 0.33 mm to 0.72 mm. Session A inter-examiner reliability was excellent for the mean measurements of two, three, four, and five images taken at each location (ICC<sub>2,k</sub> = 0.913-0.954) with MDC<sub>95</sub> ranging from 0.47 mm to 2.96 mm. Session B inter-examiner reliability was excellent for the mean measurements of two, three, four, and five images taken at the supraumbilical and umbilical (ICC<sub>2,k</sub> = 0.94-0.98), MDC<sub>95</sub> ranging from 1.38 mm to 2.58 mm and good (ICC<sub>2,k</sub> ≥ 0.81) with MDC<sub>95</sub> ranging from 0.72 mm to 0.80 mm at the infraumbilical locations.</p><p><strong>Conclusion: </strong>Novice examiners were able to capture good-quality ultrasound images of the linea alba that allowed for good to excellent intra- and inter-examiner reliability.</p>","PeriodicalId":48699,"journal":{"name":"Physiotherapy Theory and Practice","volume":" ","pages":"2652-2660"},"PeriodicalIF":1.6000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiotherapy Theory and Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/09593985.2023.2255897","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/11 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0
Abstract
Background: With the increased interest in inter-recti distance measurement using ultrasound imaging in physiotherapy, there is a question of measurement reliability, and the importance of the examiner's experience.
Purpose: The study aimed to investigate the reliability of inter-recti distance measurement in a DICOM viewer software by an experienced radiologist. For the measurement, the radiologist used linea alba images captured by two physiotherapists who were novice examiners.
Methods: Ultrasound images were acquired by two novice examiners on repeated occasions 7 days apart (sessions A and B) in 28 nulliparous women at supraumbilical, umbilical, and infraumbilical locations along linea alba.
Results: Excellent intra-examiner reliability of inter-recti distance measurements was shown at the supraumbilical and umbilical levels (ICC2,k = 0.941-0.983) with minimal detectable change (MDC95) ranging from 1.31 mm to 2.29 mm. Infraumbilical measurements had good to excellent reliability (ICC2,k = 0.894-0.972) with MDC95 ranging from 0.33 mm to 0.72 mm. Session A inter-examiner reliability was excellent for the mean measurements of two, three, four, and five images taken at each location (ICC2,k = 0.913-0.954) with MDC95 ranging from 0.47 mm to 2.96 mm. Session B inter-examiner reliability was excellent for the mean measurements of two, three, four, and five images taken at the supraumbilical and umbilical (ICC2,k = 0.94-0.98), MDC95 ranging from 1.38 mm to 2.58 mm and good (ICC2,k ≥ 0.81) with MDC95 ranging from 0.72 mm to 0.80 mm at the infraumbilical locations.
Conclusion: Novice examiners were able to capture good-quality ultrasound images of the linea alba that allowed for good to excellent intra- and inter-examiner reliability.
期刊介绍:
The aim of Physiotherapy Theory and Practice is to provide an international, peer-reviewed forum for the publication, dissemination, and discussion of recent developments and current research in physiotherapy/physical therapy. The journal accepts original quantitative and qualitative research reports, theoretical papers, systematic literature reviews, clinical case reports, and technical clinical notes. Physiotherapy Theory and Practice; promotes post-basic education through reports, reviews, and updates on all aspects of physiotherapy and specialties relating to clinical physiotherapy.