Hui Gim Khor, Pooi Wah Lott, Azida Juana Wan Ab Kadir, Sujaya Singh, Tajunisah Iqbal
{"title":"Review of Risk Factors and Complications of Anterior Migration of Ozurdex Implant: Lessons Learnt from the Previous Reports.","authors":"Hui Gim Khor, Pooi Wah Lott, Azida Juana Wan Ab Kadir, Sujaya Singh, Tajunisah Iqbal","doi":"10.1089/jop.2023.0012","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Purpose:</i></b> Ozurdex had shown promising anatomical and functional outcomes in managing refractory Irvine-Gass syndrome over the years. Burgeoning usage of Ozurdex has prompted the study of its related complications, particularly the anterior chamber migration of the implant. <b><i>Methods:</i></b> Literature reviews on the anterior chamber migration of the Ozurdex via PubMed, EBSCO, and TRIP databases were searched from 2012 to 2020. The predisposing factors, outcomes, and management of such cases were evaluated. <b><i>Results:</i></b> A total of 54 articles consisting of 105 cases of anterior migration of Ozurdex were included in this analysis. The vitrectomized eye and compromised posterior capsule were highly associated with this complication. About 81.9% of the cases had cornea edema upon presentation, with 31.4% of them ending up with cornea decompensation despite intervention. Although there was high intraocular pressure reported initially in 22 cases, only 2 cases required glaucoma filtration surgeries in which they had preexisting glaucoma. Numerous techniques of repositioning or surgical removal of the implant were described but they were challenging and the outcomes varied. <b><i>Conclusions:</i></b> A noninvasive method of manipulating the Ozurdex into the vitreous cavity via the \"Trendelenburg position, external pressure with head positioning\" maneuvers is safe yet achieves a favorable outcome. Precaution must be taken whenever offering Ozurdex to the high-risk eyes. Prompt repositioning or removal of the implant is crucial to deter cornea decompensation. Clinical Trial Registration number: NMRR-22-02092-S9X (from the Medical Research and Ethics Committee (MREC), Ministry of Health, Malaysia).</p>","PeriodicalId":16689,"journal":{"name":"Journal of Ocular Pharmacology and Therapeutics","volume":" ","pages":"342-360"},"PeriodicalIF":1.9000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ocular Pharmacology and Therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/jop.2023.0012","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/7 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Ozurdex had shown promising anatomical and functional outcomes in managing refractory Irvine-Gass syndrome over the years. Burgeoning usage of Ozurdex has prompted the study of its related complications, particularly the anterior chamber migration of the implant. Methods: Literature reviews on the anterior chamber migration of the Ozurdex via PubMed, EBSCO, and TRIP databases were searched from 2012 to 2020. The predisposing factors, outcomes, and management of such cases were evaluated. Results: A total of 54 articles consisting of 105 cases of anterior migration of Ozurdex were included in this analysis. The vitrectomized eye and compromised posterior capsule were highly associated with this complication. About 81.9% of the cases had cornea edema upon presentation, with 31.4% of them ending up with cornea decompensation despite intervention. Although there was high intraocular pressure reported initially in 22 cases, only 2 cases required glaucoma filtration surgeries in which they had preexisting glaucoma. Numerous techniques of repositioning or surgical removal of the implant were described but they were challenging and the outcomes varied. Conclusions: A noninvasive method of manipulating the Ozurdex into the vitreous cavity via the "Trendelenburg position, external pressure with head positioning" maneuvers is safe yet achieves a favorable outcome. Precaution must be taken whenever offering Ozurdex to the high-risk eyes. Prompt repositioning or removal of the implant is crucial to deter cornea decompensation. Clinical Trial Registration number: NMRR-22-02092-S9X (from the Medical Research and Ethics Committee (MREC), Ministry of Health, Malaysia).
期刊介绍:
Journal of Ocular Pharmacology and Therapeutics is the only peer-reviewed journal that combines the fields of ophthalmology and pharmacology to enable optimal treatment and prevention of ocular diseases and disorders. The Journal delivers the latest discoveries in the pharmacokinetics and pharmacodynamics of therapeutics for the treatment of ophthalmic disorders.
Journal of Ocular Pharmacology and Therapeutics coverage includes:
Glaucoma
Cataracts
Retinal degeneration
Ocular infection, trauma, and toxicology
Ocular drug delivery and biotransformation
Ocular pharmacotherapy/clinical trials
Ocular inflammatory and immune disorders
Gene and cell-based therapies
Ocular metabolic disorders
Ocular ischemia and blood flow
Proliferative disorders of the eye
Eyes on Drug Discovery - written by Gary D. Novack, PhD, featuring the latest updates on drug and device pipeline developments as well as policy/regulatory changes by the FDA.