{"title":"The first successful desensitization protocol in exenatide allergy: a case report.","authors":"Osman Ozan Yeğit,&nbsp;Göktuğ Sarıbeyliler,&nbsp;Pelin Karadağ,&nbsp;Semra Demir,&nbsp;Nurdan Gül,&nbsp;Derya Ünal,&nbsp;Aslı Gelincik Akkor","doi":"10.1186/s13223-023-00761-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Glucagon-like peptide-1 (GLP-1) receptor agonists are important treatment options in obese patients with type 2 diabetes. To date, few immediate allergic reactions due to GLP-1 receptor agonists were reported. One report revealed that a patient with a level 1 anaphylaxis according to Brighton Criteria due to an exendin based GLP-1 receptor agonist was able to tolerate liraglutide (Human GLP-1 analogue), the alternative GLP-1 receptor agonist. Since exenatide is the only available GLP-1 receptor agonist covered by insurance in Turkey, a drug desensitization protocol, the only therapeutic method in hypersensitivity reactions used in case of absence of an alternative drug, was considered. Here, we report a successful desensitization protocol for the first time in two obese diabetic patients with an immediate hypersensitivity to exenatide.</p><p><strong>Case presentation: </strong>The first patient was a 47 year-old female. She was referred to our outpatient allergy clinic because of a generalized urticaria developed within minutes after the last dose, following a week of an exenatide BID 5 mcg/20 mcl treatment. Although the reaction was sudden onset, it did not meet the Brighton Criteria of anaphylaxis. The second patient was a 46 year-old female. She had a large local immediate injection site reaction that appeared 15 min following an exenatide BID 5 mcg/20 mcl injection. The injection site reaction was not accompanied by a systemic allergic reaction. We performed desensitization with exenatide to two patients who need GLP-1 receptor agonist treatment. Protocol was completed in 7 steps in approximately 3 h, with the aim of reaching the daily dosage of exenatide. Throughout this process, we observed that both cases tolerated the protocol without any complaints or complications. Following the protocol, the patients safely tolerated the treatment for 3 months.</p><p><strong>Conclusions: </strong>We present the first successful desensitization protocol to exenatide in both local and/or systemic immediate hypersensitivity reactions and indicate the importance of desensitization in patients who do not have alternative therapies.</p>","PeriodicalId":7702,"journal":{"name":"Allergy, Asthma, and Clinical Immunology : Official Journal of the Canadian Society of Allergy and Clinical Immunology","volume":"19 1","pages":"2"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9838064/pdf/","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Allergy, Asthma, and Clinical Immunology : Official Journal of the Canadian Society of Allergy and Clinical Immunology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s13223-023-00761-y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Background: Glucagon-like peptide-1 (GLP-1) receptor agonists are important treatment options in obese patients with type 2 diabetes. To date, few immediate allergic reactions due to GLP-1 receptor agonists were reported. One report revealed that a patient with a level 1 anaphylaxis according to Brighton Criteria due to an exendin based GLP-1 receptor agonist was able to tolerate liraglutide (Human GLP-1 analogue), the alternative GLP-1 receptor agonist. Since exenatide is the only available GLP-1 receptor agonist covered by insurance in Turkey, a drug desensitization protocol, the only therapeutic method in hypersensitivity reactions used in case of absence of an alternative drug, was considered. Here, we report a successful desensitization protocol for the first time in two obese diabetic patients with an immediate hypersensitivity to exenatide.

Case presentation: The first patient was a 47 year-old female. She was referred to our outpatient allergy clinic because of a generalized urticaria developed within minutes after the last dose, following a week of an exenatide BID 5 mcg/20 mcl treatment. Although the reaction was sudden onset, it did not meet the Brighton Criteria of anaphylaxis. The second patient was a 46 year-old female. She had a large local immediate injection site reaction that appeared 15 min following an exenatide BID 5 mcg/20 mcl injection. The injection site reaction was not accompanied by a systemic allergic reaction. We performed desensitization with exenatide to two patients who need GLP-1 receptor agonist treatment. Protocol was completed in 7 steps in approximately 3 h, with the aim of reaching the daily dosage of exenatide. Throughout this process, we observed that both cases tolerated the protocol without any complaints or complications. Following the protocol, the patients safely tolerated the treatment for 3 months.

Conclusions: We present the first successful desensitization protocol to exenatide in both local and/or systemic immediate hypersensitivity reactions and indicate the importance of desensitization in patients who do not have alternative therapies.

Abstract Image

Abstract Image

Abstract Image

艾塞那肽过敏的第一个成功脱敏方案:一个病例报告。
背景:胰高血糖素样肽-1 (GLP-1)受体激动剂是肥胖2型糖尿病患者的重要治疗选择。迄今为止,很少有GLP-1受体激动剂引起的立即过敏反应的报道。一份报告显示,根据布莱顿标准,由于基于exendin的GLP-1受体激动剂导致1级过敏反应的患者能够耐受利拉鲁肽(人类GLP-1类似物),替代GLP-1受体激动剂。由于艾塞那肽是土耳其保险范围内唯一可用的GLP-1受体激动剂,因此考虑了药物脱敏方案,即在没有替代药物的情况下使用的超敏反应的唯一治疗方法。在这里,我们首次报道了对艾塞那肽立即过敏的两名肥胖糖尿病患者的成功脱敏方案。病例介绍:第一位患者为47岁女性。她被转介到我们的过敏门诊,因为在最后一次给药后几分钟内出现了广泛性荨麻疹,在一周的艾塞那肽BID 5mcg / 20mcl治疗后。虽然反应是突然发生的,但它不符合过敏反应的布莱顿标准。第二名患者为46岁女性。她在注射艾塞那肽5mcg / 20mcl后15分钟出现了大的局部立即注射部位反应。注射部位反应未伴有全身过敏反应。我们用艾塞那肽对两名需要GLP-1受体激动剂治疗的患者进行脱敏治疗。方案分7个步骤在大约3小时内完成,目的是达到艾塞那肽的每日剂量。在整个过程中,我们观察到两例患者都能耐受该方案,没有任何投诉或并发症。按照该方案,患者安全耐受治疗3个月。结论:我们提出了第一个成功的艾塞那肽脱敏方案,用于局部和/或全身立即过敏反应,并指出脱敏对没有其他治疗方法的患者的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信