Native Whole Blood (TRUE-NATEM) and Recalcified Citrated Blood (NATEM) Reference Value Validation with ROTEM Delta.

IF 1.1 Q3 ANESTHESIOLOGY
Uzung Yoon
{"title":"Native Whole Blood (TRUE-NATEM) and Recalcified Citrated Blood (NATEM) Reference Value Validation with ROTEM Delta.","authors":"Uzung Yoon","doi":"10.1177/10892532231151528","DOIUrl":null,"url":null,"abstract":"<p><p><i>Background:</i> Thromboelastography is a viscoelastic test of whole blood hemostasis. Currently, no reference value exists for native whole blood and recalcified citrated blood without activators. The aim of this study was to compare the results of ROTEM<sup>®</sup> tests using fresh native blood without decalcification \"TRUE-NATEM\" with those using decalcified citrated blood \"NATEM\" and provide reference values for each. <i>Methods:</i> Inclusion criteria were healthy adult volunteers (18-65 years). Exclusion criteria were any medical condition or medication affecting coagulation. Native whole blood testing was defined as \"TRUE-NATEM-test.\" For recalcified citrated blood testing, the NATEM function was used on ROTEM<sup>®</sup>. <i>Result:</i> The reference value for TRUE-NATEM was CT: 872-1595s, A10: 14-34 mm, A20: 26-48 mm, CFT: 314-839s, MCF: 34-55 mm, and alpha angle: 17-40°. The reference value for NATEM was CT: 757-1327s, A10: 19-43 mm, A20: 33-55 mm, CFT: 219-615s, MCF: 37-61 mm, alpha angle: 24-51°, and ML: 0-3%. When comparing the reference value of NATEM to TRUE-NATEM, the CT and CFT values are decreased and the MCF and alpha angle are increased. The recalcification process of citrated blood in NATEM shows significant activation of coagulation. Female healthy volunteers had enhanced coagulation when activators were used. Age-related statistical difference was seen when activators were used. Ethnicity did not show any difference on the ROTEM values. <i>Conclusion:</i> We determined the reference value for native whole blood and recalcified whole blood using ROTEM®. A significant discrepancy in native whole blood and recalcified citrated blood coagulation was found. Our study underlines the importance of native whole blood as the gold standard reference value in coagulation.</p>","PeriodicalId":46500,"journal":{"name":"Seminars in Cardiothoracic and Vascular Anesthesia","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Seminars in Cardiothoracic and Vascular Anesthesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/10892532231151528","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/11 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 1

Abstract

Background: Thromboelastography is a viscoelastic test of whole blood hemostasis. Currently, no reference value exists for native whole blood and recalcified citrated blood without activators. The aim of this study was to compare the results of ROTEM® tests using fresh native blood without decalcification "TRUE-NATEM" with those using decalcified citrated blood "NATEM" and provide reference values for each. Methods: Inclusion criteria were healthy adult volunteers (18-65 years). Exclusion criteria were any medical condition or medication affecting coagulation. Native whole blood testing was defined as "TRUE-NATEM-test." For recalcified citrated blood testing, the NATEM function was used on ROTEM®. Result: The reference value for TRUE-NATEM was CT: 872-1595s, A10: 14-34 mm, A20: 26-48 mm, CFT: 314-839s, MCF: 34-55 mm, and alpha angle: 17-40°. The reference value for NATEM was CT: 757-1327s, A10: 19-43 mm, A20: 33-55 mm, CFT: 219-615s, MCF: 37-61 mm, alpha angle: 24-51°, and ML: 0-3%. When comparing the reference value of NATEM to TRUE-NATEM, the CT and CFT values are decreased and the MCF and alpha angle are increased. The recalcification process of citrated blood in NATEM shows significant activation of coagulation. Female healthy volunteers had enhanced coagulation when activators were used. Age-related statistical difference was seen when activators were used. Ethnicity did not show any difference on the ROTEM values. Conclusion: We determined the reference value for native whole blood and recalcified whole blood using ROTEM®. A significant discrepancy in native whole blood and recalcified citrated blood coagulation was found. Our study underlines the importance of native whole blood as the gold standard reference value in coagulation.

用ROTEM-Delta验证天然全血(TRUE-NATEM)和再钙化柠檬酸血(NATEM)参考值。
背景:血栓弹性成像是一种全血止血的粘弹性测试。目前,不含激活剂的天然全血和难钙化柠檬酸血没有参考价值。本研究的目的是比较使用未脱钙的新鲜天然血液“TRUE-NATEM”和使用脱钙柠檬酸血液“NATEM”的ROTEM®测试结果,并为每种测试提供参考值。方法:纳入标准为健康成年志愿者(18-65岁)。排除标准为任何影响凝血的疾病或药物。天然全血检测被定义为“真正的NATEM检测”。对于顽固的柠檬酸盐血液检测,在ROTEM®上使用NATEM功能。结果:TRUE-NATEM的参考值为CT:872-1595s,A10:14-34mm,A20:26-48mm,CFT:314-839s,MCF:34-55mm,α角:17-40°。NATEM的参考值为CT:757-1327s,A10:19-43mm,A20:33-55mm,CFT:219-615s,MCF:37-61mm,α角:24-51°,ML:0-3%。当将NATEM的参考值与TRUE-NATEM进行比较时,CT和CFT值减小,MCF和α角增大。柠檬酸血在NATEM中的再钙化过程显示出显著的凝血激活。当使用激活剂时,女性健康志愿者的凝血功能增强。当使用激活剂时,发现了与年龄相关的统计差异。种族对ROTEM值没有任何差异。结论:我们使用ROTEM®确定了天然全血和难钙化全血的参考值。发现天然全血和难钙化的柠檬酸盐凝血存在显著差异。我们的研究强调了天然全血作为凝血黄金标准参考值的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.60
自引率
14.30%
发文量
31
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信