Tobias Kummer, Kelli J Mohn, Abigail J Bardwell, James H Boyum
{"title":"Evaluation of Soft-Tissue Hematomas With Real-Time, Contrast-Enhanced Ultrasound: A Pilot Study With Preliminary Findings.","authors":"Tobias Kummer, Kelli J Mohn, Abigail J Bardwell, James H Boyum","doi":"10.1097/RUQ.0000000000000621","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>In this study, we investigated the feasibility of using contrast-enhanced ultrasound (CEUS) to detect active hemorrhage in patients presenting with soft-tissue hematomas. Adult patients with clinically suspected, actively bleeding hematomas were prospectively enrolled. Contrast-enhanced ultrasound was used to assess for contrast extravasation. Ultrasound results were compared with those of multidetector computed tomographic (MDCT) imaging, operative findings, and clinical course. Sixteen patients (9 women, 7 men; mean age, 69 [SD, 13] years) were enrolled. Thirteen patients underwent MDCT imaging during their initial visit, and for 11, CEUS and computed tomography (CT) findings were concordant. The remaining patients had a negative CEUS study that was consistent with their clinical course. In 8 patients, CT imaging showed active extravasation (6 arterial, 1 indeterminate, 1 slow venous). Contrast-enhanced ultrasound and CT findings were concordant for all cases of arterial bleeding. For 1 patient, CEUS provided superior diagnostic information by identifying a pseudoaneurysm. The 2 discrepant patient cases had a ≥3-hour delay between CT and CEUS, and in 1 patient, CEUS was limited by body habitus. The second patient had no active bleeding identified in the operating room. Compared with CT, CEUS had a sensitivity and specificity of 75% and 100%, respectively, and positive and negative predictive values were 100% and 71%, respectively. Diagnostic accuracy was 85% in this limited study. Contrast-enhanced ultrasound is a promising alternative to MDCT in select patients and may sometimes provide superior clinical information. Limiting factors are large hematoma size, unfavorable anatomic location, and body habitus.</p>","PeriodicalId":49116,"journal":{"name":"Ultrasound Quarterly","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound Quarterly","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RUQ.0000000000000621","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract: In this study, we investigated the feasibility of using contrast-enhanced ultrasound (CEUS) to detect active hemorrhage in patients presenting with soft-tissue hematomas. Adult patients with clinically suspected, actively bleeding hematomas were prospectively enrolled. Contrast-enhanced ultrasound was used to assess for contrast extravasation. Ultrasound results were compared with those of multidetector computed tomographic (MDCT) imaging, operative findings, and clinical course. Sixteen patients (9 women, 7 men; mean age, 69 [SD, 13] years) were enrolled. Thirteen patients underwent MDCT imaging during their initial visit, and for 11, CEUS and computed tomography (CT) findings were concordant. The remaining patients had a negative CEUS study that was consistent with their clinical course. In 8 patients, CT imaging showed active extravasation (6 arterial, 1 indeterminate, 1 slow venous). Contrast-enhanced ultrasound and CT findings were concordant for all cases of arterial bleeding. For 1 patient, CEUS provided superior diagnostic information by identifying a pseudoaneurysm. The 2 discrepant patient cases had a ≥3-hour delay between CT and CEUS, and in 1 patient, CEUS was limited by body habitus. The second patient had no active bleeding identified in the operating room. Compared with CT, CEUS had a sensitivity and specificity of 75% and 100%, respectively, and positive and negative predictive values were 100% and 71%, respectively. Diagnostic accuracy was 85% in this limited study. Contrast-enhanced ultrasound is a promising alternative to MDCT in select patients and may sometimes provide superior clinical information. Limiting factors are large hematoma size, unfavorable anatomic location, and body habitus.
期刊介绍:
Ultrasound Quarterly provides coverage of the newest, most sophisticated ultrasound techniques as well as in-depth analysis of important developments in this dynamic field. The journal publishes reviews of a wide variety of topics including trans-vaginal ultrasonography, detection of fetal anomalies, color Doppler flow imaging, pediatric ultrasonography, and breast sonography.
Official Journal of the Society of Radiologists in Ultrasound