Contrast-enhanced ultrasonography of the placental barrier; the protective umbrella of the fetus during pregnancy.

IF 1.8 4区 医学 Q2 ACOUSTICS
Qingzi Chen, Lishao Zhang, Tianti Li, Shaoqi Chen
{"title":"Contrast-enhanced ultrasonography of the placental barrier; the protective umbrella of the fetus during pregnancy.","authors":"Qingzi Chen,&nbsp;Lishao Zhang,&nbsp;Tianti Li,&nbsp;Shaoqi Chen","doi":"10.11152/mu-3577","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Ultrasonography is the preferred technique to evaluate the status of maternal and fetal health during pregnancy. Non-obstetric acute or chronic conditions occurring during pregnancy must be diagnosed as early as possible to permit timely and necessary treatment for the sake of maternal and fetal health. The purpose of this study was to evaluate the safety and value of contrast-enhanced ultrasonography (CEUS) during pregnancy.</p><p><strong>Materials and methods: </strong>This prospective study included 14 pregnant women requiring pregnancy termination and six healthy pregnant women. The 14 pregnant women requiring pregnancy termination underwent CEUS prior to surgery to investigate the pattern of contrast agent diffusion. The six healthy pregnant women did not undergo CEUS. The structure of placentae with and without contrast agent injection were also compared by light microscopy.</p><p><strong>Results: </strong>CEUS analysis failed to identify any signs of contrast agents in the umbilical cord blood and fetus. There were no obvious changes in the morphology of placentae with and without contrast agent injection under light microscope. CEUS identified the need for early treatment in one pregnant woman with an ovarian tumor.</p><p><strong>Conclusions: </strong>Due to the protective effect of the placental barrier on the fetus, CEUS during pregnancy may represent a safe form of imaging technology that can provide valuable information for the diagnosis of non-obstetric acute or chronic disorders and to guide thefuture treatment of pregnant women.</p>","PeriodicalId":48781,"journal":{"name":"Medical Ultrasonography","volume":"24 4","pages":"427-433"},"PeriodicalIF":1.8000,"publicationDate":"2022-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Ultrasonography","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11152/mu-3577","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 1

Abstract

Aims: Ultrasonography is the preferred technique to evaluate the status of maternal and fetal health during pregnancy. Non-obstetric acute or chronic conditions occurring during pregnancy must be diagnosed as early as possible to permit timely and necessary treatment for the sake of maternal and fetal health. The purpose of this study was to evaluate the safety and value of contrast-enhanced ultrasonography (CEUS) during pregnancy.

Materials and methods: This prospective study included 14 pregnant women requiring pregnancy termination and six healthy pregnant women. The 14 pregnant women requiring pregnancy termination underwent CEUS prior to surgery to investigate the pattern of contrast agent diffusion. The six healthy pregnant women did not undergo CEUS. The structure of placentae with and without contrast agent injection were also compared by light microscopy.

Results: CEUS analysis failed to identify any signs of contrast agents in the umbilical cord blood and fetus. There were no obvious changes in the morphology of placentae with and without contrast agent injection under light microscope. CEUS identified the need for early treatment in one pregnant woman with an ovarian tumor.

Conclusions: Due to the protective effect of the placental barrier on the fetus, CEUS during pregnancy may represent a safe form of imaging technology that can provide valuable information for the diagnosis of non-obstetric acute or chronic disorders and to guide thefuture treatment of pregnant women.

胎盘屏障的超声造影检查;胎儿在怀孕期间的保护伞。
目的:超声检查是评估妊娠期母胎健康状况的首选技术。怀孕期间发生的非产科急性或慢性疾病必须尽早诊断,以便及时和必要的治疗,以确保母婴健康。本研究的目的是评价超声造影(CEUS)在妊娠期间的安全性和价值。材料与方法:本前瞻性研究纳入14例需要终止妊娠的孕妇和6例健康孕妇。14例需要终止妊娠的孕妇在手术前行超声造影以研究造影剂的扩散模式。6名健康孕妇未接受超声造影。在光镜下对注射造影剂前后胎盘的结构进行了比较。结果:超声造影分析未能在脐带血和胎儿中发现任何造影剂的迹象。光镜下对比剂注射前后胎盘形态无明显变化。超声造影(CEUS)发现有必要对一名患有卵巢肿瘤的孕妇进行早期治疗。结论:由于胎盘屏障对胎儿的保护作用,妊娠期超声检查可能是一种安全的成像技术,可以为非产科急性或慢性疾病的诊断提供有价值的信息,并指导孕妇未来的治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical Ultrasonography
Medical Ultrasonography RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.20
自引率
5.90%
发文量
79
期刊介绍: The journal aims to promote ultrasound diagnosis by publishing papers in a variety of categories, including editorial letters, original papers, review articles, pictorial essays, technical developments, case reports, letters to the editor or occasional special reports (fundamental, clinical as well as methodological and educational papers). The papers published cover the whole spectrum of the applications of diagnostic medical ultrasonography, including basic science and therapeutic applications. The journal hosts information regarding the society''s activities, scheduling of accredited training courses in ultrasound diagnosis, as well as the agenda of national and international scientific events.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信