Biocompatibility of an experimental endodontic sealer (Resil) in comparison with AH26 and AH-Plus in rats: An animal study.

Q4 Dentistry
Hengameh Ashraf, Parviz Shafagh, Fatemeh Mashhadi Abbas, Soolmaz Heidari, Hossein Shahoon, Amin Zandian, Leila Aghajanpour, Saeede Zadsirjan
{"title":"Biocompatibility of an experimental endodontic sealer (Resil) in comparison with AH26 and AH-Plus in rats: An animal study.","authors":"Hengameh Ashraf, Parviz Shafagh, Fatemeh Mashhadi Abbas, Soolmaz Heidari, Hossein Shahoon, Amin Zandian, Leila Aghajanpour, Saeede Zadsirjan","doi":"10.34172/joddd.2022.019","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background.</b> This experimental study sought to assess the biocompatibility of Resil, an experimental epoxy resin-based sealer, in comparison with AH26 and AH-Plus sealers in rats. <b>Methods.</b> Twelve male Wistar rats weighing 400 to 500 grams were evaluated in this experimental study. Four polyethylene tubes containing Resil, AH-Plus, AH26 sealers, and an empty tube were implanted subcutaneously in rats. The degree of inflammation, type of inflammatory cells present, foreign body reaction, quality of connective tissue, and presence of fibrotic capsule were evaluated histopathologically at 7 and 30 days after implanting the tubes to assess the biocompatibility of sealers. Data were analyzed using the Chi-square test. <b>Results.</b> At 7 days, the degree of inflammation in Resil group was almost similar to AH26 group, and 66.7% of rats showed moderate inflammation. AH-Plus group showed less inflammation than Resil and AH26 (50% of rats showed low degree of inflammation), At 30 days, the inflammatory status of all groups was the same, and 83.3% of rats showed very low degree of inflammation. The inflammatory response during the experiment decreased from day 7 to day 30 in all groups. The neutrophil count (<i>P</i>=0.00), fibrotic capsule (<i>P</i>=0.01) and the amount of granulation tissue (<i>P</i>=0.05) significantly decreased from day 7 to day 30 in Resil group. <b>Conclusion.</b> Resil sealer showed appropriate biocompatibility at 7 and 30 days after subcutaneous implantation in rats, comparable to AH26 and AH-Plus. Clinical studies are required to confirm these results.</p>","PeriodicalId":15599,"journal":{"name":"Journal of Dental Research, Dental Clinics, Dental Prospects","volume":"16 2","pages":"112-117"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9763656/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dental Research, Dental Clinics, Dental Prospects","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/joddd.2022.019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/10/15 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Background. This experimental study sought to assess the biocompatibility of Resil, an experimental epoxy resin-based sealer, in comparison with AH26 and AH-Plus sealers in rats. Methods. Twelve male Wistar rats weighing 400 to 500 grams were evaluated in this experimental study. Four polyethylene tubes containing Resil, AH-Plus, AH26 sealers, and an empty tube were implanted subcutaneously in rats. The degree of inflammation, type of inflammatory cells present, foreign body reaction, quality of connective tissue, and presence of fibrotic capsule were evaluated histopathologically at 7 and 30 days after implanting the tubes to assess the biocompatibility of sealers. Data were analyzed using the Chi-square test. Results. At 7 days, the degree of inflammation in Resil group was almost similar to AH26 group, and 66.7% of rats showed moderate inflammation. AH-Plus group showed less inflammation than Resil and AH26 (50% of rats showed low degree of inflammation), At 30 days, the inflammatory status of all groups was the same, and 83.3% of rats showed very low degree of inflammation. The inflammatory response during the experiment decreased from day 7 to day 30 in all groups. The neutrophil count (P=0.00), fibrotic capsule (P=0.01) and the amount of granulation tissue (P=0.05) significantly decreased from day 7 to day 30 in Resil group. Conclusion. Resil sealer showed appropriate biocompatibility at 7 and 30 days after subcutaneous implantation in rats, comparable to AH26 and AH-Plus. Clinical studies are required to confirm these results.

Abstract Image

Abstract Image

Abstract Image

实验性牙髓封闭剂(Resil)与 AH26 和 AH-Plus 在大鼠体内的生物相容性比较:一项动物研究。
背景。本实验研究旨在评估一种实验性环氧树脂封闭剂 Resil 与 AH26 和 AH-Plus 封闭剂在大鼠体内的生物相容性。研究方法。本实验研究评估了 12 只体重 400 至 500 克的雄性 Wistar 大鼠。将含有 Resil、AH-Plus、AH26 封闭剂的四根聚乙烯管和一根空管植入大鼠皮下。在植入管子 7 天和 30 天后,对炎症程度、炎症细胞类型、异物反应、结缔组织质量和纤维囊的存在进行组织病理学评估,以评估密封剂的生物相容性。数据采用卡方检验进行分析。结果7 天时,Resil 组大鼠的炎症程度与 AH26 组几乎相似,66.7% 的大鼠表现为中度炎症。AH-Plus 组的炎症程度低于 Resil 组和 AH26 组(50% 的大鼠表现为低度炎症),30 天时,各组的炎症状况相同,83.3% 的大鼠表现为极低度炎症。实验期间,从第 7 天到第 30 天,各组大鼠的炎症反应均有所下降。从第 7 天到第 30 天,Resil 组的中性粒细胞计数(P=0.00)、纤维囊(P=0.01)和肉芽组织量(P=0.05)均显著下降。结论Resil 封闭剂在大鼠皮下植入 7 天和 30 天后显示出适当的生物相容性,与 AH26 和 AH-Plus 相当。这些结果还需要临床研究来证实。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.40
自引率
0.00%
发文量
23
审稿时长
25 weeks
期刊介绍: Journal of Dental Research Dental Clinics Dental Prospects (JODDD) is a Platinum* Open Access, peer-reviewed quarterly indexed journal that publishes articles of basic, clinical, and prospective nature in all areas of dentistry and oral health.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信