Dynamic Ranges of Retinal Nerve Fiber and Optic Nerve Head Parameters Measured Using Optical Coherence Tomography in Glaucoma: A Longitudinal Study.

Q3 Medicine
Nala Shin, Gi Seok Park, Kyung Nam Kim, Young Hoon Hwang
{"title":"Dynamic Ranges of Retinal Nerve Fiber and Optic Nerve Head Parameters Measured Using Optical Coherence Tomography in Glaucoma: A Longitudinal Study.","authors":"Nala Shin,&nbsp;Gi Seok Park,&nbsp;Kyung Nam Kim,&nbsp;Young Hoon Hwang","doi":"10.3341/kjo.2022.0048","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the dynamic range of retinal nerve fiber layer (RNFL) and optic nerve head (ONH) parameters measured using optical coherence tomography (OCT) in conditions ranging from nonglaucomatous status to advanced glaucoma by longitudinal observation.</p><p><strong>Methods: </strong>A total of 15 eyes from 12 participants with glaucoma progression from a nonglaucomatous status to advanced glaucoma were included. The RNFL and ONH parameters were compared between the nonglaucomatous and advanced stages within the same eye. The absolute and relative changes in OCT parameters were analyzed.</p><p><strong>Results: </strong>The median highest intraocular pressure was 42.5 mmHg (interquartile range, 37.5 to 54.5 mmHg), and the final mean deviation of the visual field test was -24.68 dB (interquartile range, -23.93 to -31.13 dB). The median relative changes in RNFL thickness were -40.6% in the overall area, and -51.9%, -21.4%, -51.1%, and -41.8% in the superior, nasal, inferior, and temporal quadrants, respectively (all p < 0.05). Relative changes in the rim area, disc area, average cup to disc ratio, vertical cup to disc ratio, and cup volume were -56.64%, 0.59%, 62.10%, 66.0%, and 337.90%, respectively (all p < 0.05, except for disc area with a p-value of 0.753).</p><p><strong>Conclusions: </strong>The dynamic range of the RNFL thickness ranged from 40.6% to 51.9%, and the dynamic range of the ONH parameters ranged from 56.64% to 337.90%. During the course of glaucoma progression, the cup volume showed the widest dynamic range. However, the disc area did not show significant changes.</p>","PeriodicalId":17883,"journal":{"name":"Korean Journal of Ophthalmology : KJO","volume":"36 6","pages":"493-500"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/61/19/kjo-2022-0048.PMC9745349.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Ophthalmology : KJO","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3341/kjo.2022.0048","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the dynamic range of retinal nerve fiber layer (RNFL) and optic nerve head (ONH) parameters measured using optical coherence tomography (OCT) in conditions ranging from nonglaucomatous status to advanced glaucoma by longitudinal observation.

Methods: A total of 15 eyes from 12 participants with glaucoma progression from a nonglaucomatous status to advanced glaucoma were included. The RNFL and ONH parameters were compared between the nonglaucomatous and advanced stages within the same eye. The absolute and relative changes in OCT parameters were analyzed.

Results: The median highest intraocular pressure was 42.5 mmHg (interquartile range, 37.5 to 54.5 mmHg), and the final mean deviation of the visual field test was -24.68 dB (interquartile range, -23.93 to -31.13 dB). The median relative changes in RNFL thickness were -40.6% in the overall area, and -51.9%, -21.4%, -51.1%, and -41.8% in the superior, nasal, inferior, and temporal quadrants, respectively (all p < 0.05). Relative changes in the rim area, disc area, average cup to disc ratio, vertical cup to disc ratio, and cup volume were -56.64%, 0.59%, 62.10%, 66.0%, and 337.90%, respectively (all p < 0.05, except for disc area with a p-value of 0.753).

Conclusions: The dynamic range of the RNFL thickness ranged from 40.6% to 51.9%, and the dynamic range of the ONH parameters ranged from 56.64% to 337.90%. During the course of glaucoma progression, the cup volume showed the widest dynamic range. However, the disc area did not show significant changes.

Abstract Image

Abstract Image

使用光学相干断层扫描测量青光眼视网膜神经纤维和视神经头参数的动态范围:纵向研究。
目的:通过纵向观察,评价光学相干断层扫描(OCT)在非青光眼状态到晚期青光眼状态下视网膜神经纤维层(RNFL)和视神经头(ONH)参数的动态范围。方法:12例青光眼从非青光眼发展到晚期青光眼的患者共15只眼。比较同眼非青光眼和晚期青光眼的RNFL和ONH参数。分析OCT参数的绝对变化和相对变化。结果:眼压最高中位数为42.5 mmHg(四分位数范围为37.5 ~ 54.5 mmHg),视野测试最终平均偏差为-24.68 dB(四分位数范围为-23.93 ~ -31.13 dB)。RNFL厚度的中位相对变化在整个区域为-40.6%,在上、鼻、下、颞象限分别为-51.9%、-21.4%、-51.1%、-41.8%(均p < 0.05)。边缘面积、椎间盘面积、平均杯盘比、垂直杯盘比和杯体积的相对变化分别为-56.64%、0.59%、62.10%、66.0%和337.90% (p < 0.05,椎间盘面积p值为0.753)。结论:RNFL厚度动态范围为40.6% ~ 51.9%,ONH参数动态范围为56.64% ~ 337.90%。在青光眼的发展过程中,杯容积表现出最宽的动态范围。但椎间盘面积未见明显变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Korean Journal of Ophthalmology : KJO
Korean Journal of Ophthalmology : KJO Medicine-Ophthalmology
CiteScore
2.40
自引率
0.00%
发文量
84
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信