Optimization design of two-stage amplification micro-drive system without additional motion based on particle swarm optimization algorithm.

4区 计算机科学 Q1 Arts and Humanities
Manzhi Yang, Kaiyang Wei, Chuanwei Zhang, Dandan Liu, Yizhi Yang, Feiyan Han, Shuanfeng Zhao
{"title":"Optimization design of two-stage amplification micro-drive system without additional motion based on particle swarm optimization algorithm.","authors":"Manzhi Yang,&nbsp;Kaiyang Wei,&nbsp;Chuanwei Zhang,&nbsp;Dandan Liu,&nbsp;Yizhi Yang,&nbsp;Feiyan Han,&nbsp;Shuanfeng Zhao","doi":"10.1186/s42492-022-00124-1","DOIUrl":null,"url":null,"abstract":"<p><p>With the increasing requirements of precision mechanical systems in electronic packaging, ultra-precision machining, biomedicine and other high-tech fields, it is necessary to study a precision two-stage amplification micro-drive system that can safely provide high precision and a large amplification ratio. In view of the disadvantages of the current two-stage amplification and micro-drive system, such as poor security, low motion accuracy and limited amplification ratio, an optimization design of a precise symmetrical two-stage amplification micro-drive system was completed in this study, and its related performance was studied. Based on the guiding principle of the flexure hinge, a two-stage amplification micro-drive mechanism with no parasitic motion or non-motion direction force was designed. In addition, the structure optimization design of the mechanism was completed using the particle swarm optimization algorithm, which increased the amplification ratio of the mechanism from 5 to 18 times. A precise symmetrical two-stage amplification system was designed using a piezoelectric ceramic actuator and two-stage amplification micro-drive mechanism as the micro-driver and actuator, respectively. The driving, strength, and motion performances of the system were subsequently studied. The results showed that the driving linearity of the system was high, the strength satisfied the design requirements, the motion amplification ratio was high and the motion accuracy was high (relative error was 5.31%). The research in this study can promote the optimization of micro-drive systems.</p>","PeriodicalId":52384,"journal":{"name":"Visual Computing for Industry, Biomedicine, and Art","volume":"5 1","pages":"28"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9700539/pdf/","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Visual Computing for Industry, Biomedicine, and Art","FirstCategoryId":"1093","ListUrlMain":"https://doi.org/10.1186/s42492-022-00124-1","RegionNum":4,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Arts and Humanities","Score":null,"Total":0}
引用次数: 3

Abstract

With the increasing requirements of precision mechanical systems in electronic packaging, ultra-precision machining, biomedicine and other high-tech fields, it is necessary to study a precision two-stage amplification micro-drive system that can safely provide high precision and a large amplification ratio. In view of the disadvantages of the current two-stage amplification and micro-drive system, such as poor security, low motion accuracy and limited amplification ratio, an optimization design of a precise symmetrical two-stage amplification micro-drive system was completed in this study, and its related performance was studied. Based on the guiding principle of the flexure hinge, a two-stage amplification micro-drive mechanism with no parasitic motion or non-motion direction force was designed. In addition, the structure optimization design of the mechanism was completed using the particle swarm optimization algorithm, which increased the amplification ratio of the mechanism from 5 to 18 times. A precise symmetrical two-stage amplification system was designed using a piezoelectric ceramic actuator and two-stage amplification micro-drive mechanism as the micro-driver and actuator, respectively. The driving, strength, and motion performances of the system were subsequently studied. The results showed that the driving linearity of the system was high, the strength satisfied the design requirements, the motion amplification ratio was high and the motion accuracy was high (relative error was 5.31%). The research in this study can promote the optimization of micro-drive systems.

Abstract Image

Abstract Image

Abstract Image

基于粒子群优化算法的无附加运动两级放大微驱动系统优化设计。
随着电子封装、超精密加工、生物医药等高科技领域对精密机械系统的要求越来越高,有必要研究一种能够安全地提供高精度和大放大比的精密两级放大微驱动系统。针对目前两级放大微驱动系统存在安全性差、运动精度低、放大比受限等缺点,完成了一种精密对称两级放大微驱动系统的优化设计,并对其相关性能进行了研究。基于柔性铰链的指导原理,设计了一种无寄生运动力和无运动方向力的两级放大微驱动机构。此外,利用粒子群优化算法完成了机构的结构优化设计,使机构放大倍率从5倍提高到18倍。采用压电陶瓷作动器和两级放大微驱动机构分别作为微驱动器和作动器,设计了精密对称两级放大系统。随后研究了该系统的驱动、强度和运动性能。结果表明,该系统驱动线性度高,强度满足设计要求,运动放大比高,运动精度高(相对误差为5.31%)。本研究对微驱动系统的优化设计具有一定的促进作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Visual Computing for Industry, Biomedicine, and Art
Visual Computing for Industry, Biomedicine, and Art Arts and Humanities-Visual Arts and Performing Arts
CiteScore
5.60
自引率
0.00%
发文量
28
审稿时长
5 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信