Comparative evaluation of implant stability and crestal bone level between tapered and cylindrical implants in the posterior regions of the mandible: A prospective, randomized, split-mouth clinical trial.

National Journal of Maxillofacial Surgery Pub Date : 2023-05-01 Epub Date: 2023-07-13 DOI:10.4103/njms.njms_514_21
Poonam Wakure, Pankaj Ghalaut, Manu Rathee, Prachi Jain, Maqbul Alam, Sanju Malik
{"title":"Comparative evaluation of implant stability and crestal bone level between tapered and cylindrical implants in the posterior regions of the mandible: A prospective, randomized, split-mouth clinical trial.","authors":"Poonam Wakure,&nbsp;Pankaj Ghalaut,&nbsp;Manu Rathee,&nbsp;Prachi Jain,&nbsp;Maqbul Alam,&nbsp;Sanju Malik","doi":"10.4103/njms.njms_514_21","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the clinical outcome of tapered and cylindrical implants placed in the posterior region of mandible by measuring implant stability and crestal bone level at the healing period.</p><p><strong>Materials and methods: </strong>A prospective clinical study was conducted on 15 patients who were included in the study based on the inclusion and exclusion criteria. A total of 30 dental implants were placed in both groups: 15 implants in Group I (tapered implants) and 15 implants in Group II (cylindrical implants) in the posterior region of mandible. Implant stability assessment by periotest was done at the time of implant placement (baseline) and after 3 months. The crestal bone level was measured with the help of radiovisiography (RVG) at the time of implant placement (baseline) and at 3 and 6 months.</p><p><strong>Results: </strong>At baseline, there was statistically significant (P < 0.01) difference in primary implant stability. Tapered implants had higher primary implant stability than cylindrical implants. However, at 3 months, there was no statistically significant (P > 0.05) difference in the secondary implant stability of both the groups. Also, the crestal bone level on the mesial and distal sides of dental implant for tapered and cylindrical implants was statistically nonsignificant (P > 0.05) at all time intervals, that is, at baseline and at 3 and 6 months.</p><p><strong>Conclusion: </strong>Tapered implants had higher primary stability than cylindrical implants, and no difference was found in secondary stability. The crestal bone level was similar for both groups during early healing and early post-loading periods.</p>","PeriodicalId":18827,"journal":{"name":"National Journal of Maxillofacial Surgery","volume":"14 2","pages":"242-248"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/61/75/NJMS-14-242.PMC10474532.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"National Journal of Maxillofacial Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/njms.njms_514_21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/13 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare the clinical outcome of tapered and cylindrical implants placed in the posterior region of mandible by measuring implant stability and crestal bone level at the healing period.

Materials and methods: A prospective clinical study was conducted on 15 patients who were included in the study based on the inclusion and exclusion criteria. A total of 30 dental implants were placed in both groups: 15 implants in Group I (tapered implants) and 15 implants in Group II (cylindrical implants) in the posterior region of mandible. Implant stability assessment by periotest was done at the time of implant placement (baseline) and after 3 months. The crestal bone level was measured with the help of radiovisiography (RVG) at the time of implant placement (baseline) and at 3 and 6 months.

Results: At baseline, there was statistically significant (P < 0.01) difference in primary implant stability. Tapered implants had higher primary implant stability than cylindrical implants. However, at 3 months, there was no statistically significant (P > 0.05) difference in the secondary implant stability of both the groups. Also, the crestal bone level on the mesial and distal sides of dental implant for tapered and cylindrical implants was statistically nonsignificant (P > 0.05) at all time intervals, that is, at baseline and at 3 and 6 months.

Conclusion: Tapered implants had higher primary stability than cylindrical implants, and no difference was found in secondary stability. The crestal bone level was similar for both groups during early healing and early post-loading periods.

Abstract Image

Abstract Image

Abstract Image

下颌骨后部锥形和圆柱形种植体的种植体稳定性和冠骨水平的比较评估:一项前瞻性、随机、分口临床试验。
目的:通过测量种植体在愈合期的稳定性和冠骨水平,比较锥形和圆柱形种植体在下颌骨后部区域的临床效果。材料和方法:根据纳入和排除标准,对15名纳入研究的患者进行了前瞻性临床研究。两组共放置了30个牙种植体:第一组15个种植体(锥形种植体),第二组15个植入体(圆柱形种植体)位于下颌骨后部。periotest在植入物放置时(基线)和3个月后进行植入物稳定性评估。在植入物放置时(基线)以及在3个月和6个月时,借助放射显影术(RVG)测量冠骨水平。结果:在基线时,初次植入物的稳定性有统计学意义(P<0.01)。锥形植入物具有比圆柱形植入物更高的初次植入稳定性。然而,在3个月时,两组的二次植入稳定性没有统计学意义(P>0.05)。此外,在所有时间间隔,即基线以及3个月和6个月时,锥形和圆柱形种植体的种植体近中侧和远中侧的冠骨水平在统计学上均无统计学意义(P>0.05)。结论:锥形种植体的一期稳定性高于圆柱形种植体,二期稳定性无差异。在早期愈合和负荷后早期,两组的冠骨水平相似。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信