Time to -30°C as a predictor of acute success during cryoablation in patients with atrial fibrillation.

IF 2.5 3区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Cardiology journal Pub Date : 2023-01-01 Epub Date: 2021-10-28 DOI:10.5603/CJ.a2021.0135
Carlos Antonio Álvarez-Ortega, Miguel Angel Ruiz, César Solórzano-Guillén, Alberto Barrera, Jorge Toquero-Ramos, Jesús Daniel Martínez-Alday, Carlos Grande, José M Segura, Arcadio García-Alberola, Pablo Moriña-Vázquez, Ángel Ferrero-de-Loma-Osorio, Roger Villuendas, Cózar Rocío, Maria Fe Arcocha, Alicia Ibañez, Rafael Peinado
{"title":"Time to -30°C as a predictor of acute success during cryoablation in patients with atrial fibrillation.","authors":"Carlos Antonio Álvarez-Ortega,&nbsp;Miguel Angel Ruiz,&nbsp;César Solórzano-Guillén,&nbsp;Alberto Barrera,&nbsp;Jorge Toquero-Ramos,&nbsp;Jesús Daniel Martínez-Alday,&nbsp;Carlos Grande,&nbsp;José M Segura,&nbsp;Arcadio García-Alberola,&nbsp;Pablo Moriña-Vázquez,&nbsp;Ángel Ferrero-de-Loma-Osorio,&nbsp;Roger Villuendas,&nbsp;Cózar Rocío,&nbsp;Maria Fe Arcocha,&nbsp;Alicia Ibañez,&nbsp;Rafael Peinado","doi":"10.5603/CJ.a2021.0135","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Freezing rate of second-generation cryoballoon (CB) is a biophysical parameter that could assist pulmonary vein isolation. The aim of this study is to assess freezing rate (time to reach -30°C ([TT-30C]) as an early predictor of acute pulmonary vein isolation using the CB.</p><p><strong>Methods: </strong>Biophysical data from CB freeze applications within a multicenter, nation-wide CB ablation registry were gathered. Successful application (SA), was defined as achieving durable intraprocedural vein isolation. And SA with time to isolation under 60 s (SA-TTI<60) as achieving durable vein isolation in under 60 s. Logistic regressions were performed and predictive models were built for the data set.</p><p><strong>Results: </strong>12,488 CB applications from 1,733 atrial fibrillation (AF) ablation procedures were included within 27 centers from a Spanish CB AF ablation registry. SA was achieved in 6,349 of 9,178 (69.2%) total freeze applications, and SA-TTI<60 was obtained in 2,673 of 4,784 (55.9%) freezes where electrogram monitoring was present. TT-30C was shorter in the SA group (33.4 ± 9.2 vs 39.3 ± 12.1 s; p < 0.001) and SA-TTI<60 group (31.8 ± 7.6 vs. 38.5 ± 11.5 s; p < 0.001). Also, a 10 s increase in TT-30C was associated with a 41% reduction in the odds for an SA (odds ratio [OR] 0.59; 95% confidence interval [CI] 0.56-0.63) and a 57% reduction in the odds for achieving SA-TTI<60 (OR 0.43; 95% CI 0.39-0.49), when corrected for electrogram visualization, vein position, and application order.</p><p><strong>Conclusions: </strong>Time to reach -30°C is an early predictor of the quality of a CB application and can be used to guide the ablation procedure even in the absence of electrogram monitoring.</p>","PeriodicalId":9492,"journal":{"name":"Cardiology journal","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/d6/37/cardj-30-4-534.PMC10508066.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiology journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5603/CJ.a2021.0135","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/10/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 1

Abstract

Background: Freezing rate of second-generation cryoballoon (CB) is a biophysical parameter that could assist pulmonary vein isolation. The aim of this study is to assess freezing rate (time to reach -30°C ([TT-30C]) as an early predictor of acute pulmonary vein isolation using the CB.

Methods: Biophysical data from CB freeze applications within a multicenter, nation-wide CB ablation registry were gathered. Successful application (SA), was defined as achieving durable intraprocedural vein isolation. And SA with time to isolation under 60 s (SA-TTI<60) as achieving durable vein isolation in under 60 s. Logistic regressions were performed and predictive models were built for the data set.

Results: 12,488 CB applications from 1,733 atrial fibrillation (AF) ablation procedures were included within 27 centers from a Spanish CB AF ablation registry. SA was achieved in 6,349 of 9,178 (69.2%) total freeze applications, and SA-TTI<60 was obtained in 2,673 of 4,784 (55.9%) freezes where electrogram monitoring was present. TT-30C was shorter in the SA group (33.4 ± 9.2 vs 39.3 ± 12.1 s; p < 0.001) and SA-TTI<60 group (31.8 ± 7.6 vs. 38.5 ± 11.5 s; p < 0.001). Also, a 10 s increase in TT-30C was associated with a 41% reduction in the odds for an SA (odds ratio [OR] 0.59; 95% confidence interval [CI] 0.56-0.63) and a 57% reduction in the odds for achieving SA-TTI<60 (OR 0.43; 95% CI 0.39-0.49), when corrected for electrogram visualization, vein position, and application order.

Conclusions: Time to reach -30°C is an early predictor of the quality of a CB application and can be used to guide the ablation procedure even in the absence of electrogram monitoring.

Abstract Image

Abstract Image

Abstract Image

心房颤动患者冷冻消融期间达到-30°C的时间作为急性成功的预测因素。
背景:第二代冷冻球囊(CB)的冷冻速率是一个有助于肺静脉隔离的生物物理参数。本研究的目的是评估冷冻速率(达到-30°C([TT-30C])的时间),作为使用CB进行急性肺静脉隔离的早期预测指标。方法:收集多中心、全国范围内CB消融登记中CB冷冻应用的生物物理数据。成功应用(SA)被定义为实现持久的术中静脉隔离。SA与60 s以下的隔离时间(SA TTI结果:在西班牙CB AF消融注册中心的27个中心内,纳入了1733例心房颤动(AF)消融程序中的12488例CB应用。9178次全冷冻应用中有6349次(69.2%)达到SA,SA TTI结论:达到-30°C的时间是CB应用质量的早期预测指标,即使在没有心电图监测的情况下,也可用于指导消融程序。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Cardiology journal
Cardiology journal CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
5.10
自引率
10.30%
发文量
188
审稿时长
4-8 weeks
期刊介绍: Cardiology Journal is a scientific, peer-reviewed journal covering a broad spectrum of topics in cardiology. The journal has been published since 1994 and over the years it has become an internationally recognized journal of cardiological and medical community. Cardiology Journal is the journal for practicing cardiologists, researchers, and young trainees benefiting from broad spectrum of useful educational content.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信