The effect of light curing time and intensity on the bond strength and fracture resistance of orthodontic adhesive.

Q4 Dentistry
Omar K Mohammed, Mohammed T Younis, Alaa E Dawood
{"title":"The effect of light curing time and intensity on the bond strength and fracture resistance of orthodontic adhesive.","authors":"Omar K Mohammed,&nbsp;Mohammed T Younis,&nbsp;Alaa E Dawood","doi":"10.34172/joddd.2023.36990","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study aimed to measure the shear bond strength and compressive strength of orthodontic adhesives at different curing times and intensities.</p><p><strong>Methods: </strong>Ninety extracted human premolars were used. Orthodontic brackets were bonded on the buccal surface of the teeth with orthodontic adhesive light-cured using VRN-VAFU LED curing light at different curing times (1, 3 and 5 seconds) and intensities (1000, 1600 and 2300 mW/cm<sup>2</sup> ). A universal testing machine was used to measure the shear bond strength. The ratio of the adhesive remnant and compressive strength of the orthodontic adhesive, at each curing time at the different intensities, were also evaluated. The results were statistically analyzed using one-way analysis of variance followed by Tukey's test.</p><p><strong>Results: </strong>The lowest bond strength values (6.4, 9.9 and 12.6 MPa) were recorded with 1000 mW/ cm<sup>2</sup> intensity (at all curing times) in comparison with the other intensities (<i>P</i><0.05). Increasing the curing time significantly increased the bond strength of the orthodontic brackets (<i>P</i><0.05), except when the curing time was increased from 3 sec to 5 sec at 1600 mW/cm<sup>2</sup> intensity. The highest compressive strength values (130.3, 147.1 and 174 MPa) were recorded at 2300 mW/ cm<sup>2</sup> intensity (at all curing times) compared to the other intensities (<i>P</i><0.05). The highest values of the ratio of the adhesive remnants were recorded at 1000 mW/cm<sup>2</sup> intensity (at all curing times) compared to the other intensities (<i>P</i><0.05).</p><p><strong>Conclusion: </strong>Although, increasing the curing time and\\or the curing intensity has a positive effect on the bond strength and compressive strength of the orthodontic adhesive, it might be possible to suggest reducing the curing time of orthodontic adhesive to 1 sec at curing intensity of 2300 mW/cm<sup>2</sup>.</p>","PeriodicalId":15599,"journal":{"name":"Journal of Dental Research, Dental Clinics, Dental Prospects","volume":"17 1","pages":"23-27"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10462919/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dental Research, Dental Clinics, Dental Prospects","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/joddd.2023.36990","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Background: This study aimed to measure the shear bond strength and compressive strength of orthodontic adhesives at different curing times and intensities.

Methods: Ninety extracted human premolars were used. Orthodontic brackets were bonded on the buccal surface of the teeth with orthodontic adhesive light-cured using VRN-VAFU LED curing light at different curing times (1, 3 and 5 seconds) and intensities (1000, 1600 and 2300 mW/cm2 ). A universal testing machine was used to measure the shear bond strength. The ratio of the adhesive remnant and compressive strength of the orthodontic adhesive, at each curing time at the different intensities, were also evaluated. The results were statistically analyzed using one-way analysis of variance followed by Tukey's test.

Results: The lowest bond strength values (6.4, 9.9 and 12.6 MPa) were recorded with 1000 mW/ cm2 intensity (at all curing times) in comparison with the other intensities (P<0.05). Increasing the curing time significantly increased the bond strength of the orthodontic brackets (P<0.05), except when the curing time was increased from 3 sec to 5 sec at 1600 mW/cm2 intensity. The highest compressive strength values (130.3, 147.1 and 174 MPa) were recorded at 2300 mW/ cm2 intensity (at all curing times) compared to the other intensities (P<0.05). The highest values of the ratio of the adhesive remnants were recorded at 1000 mW/cm2 intensity (at all curing times) compared to the other intensities (P<0.05).

Conclusion: Although, increasing the curing time and\or the curing intensity has a positive effect on the bond strength and compressive strength of the orthodontic adhesive, it might be possible to suggest reducing the curing time of orthodontic adhesive to 1 sec at curing intensity of 2300 mW/cm2.

光固化时间和光固化强度对正畸胶粘剂粘结强度和抗断性的影响。
背景:本研究旨在测定正畸胶粘剂在不同固化时间和固化强度下的剪切粘结强度和抗压强度。方法:使用90颗拔除的人前磨牙。采用VRN-VAFU LED光固化光固化的正畸胶粘剂,在不同固化时间(1、3、5秒)和强度(1000、1600、2300 mW/cm2)下,将正畸托槽粘接在牙齿颊面。采用万能试验机对剪切粘结强度进行了测试。在不同强度的固化时间下,评价正畸胶粘剂残余与抗压强度的比值。结果采用单向方差分析和Tukey检验进行统计学分析。结果:与其他强度(PP2强度)相比,在1000 mW/ cm2强度下(所有固化时间)的粘结强度值最低(6.4、9.9和12.6 MPa)。在2300 mW/ cm2强度(所有养护时间)下,与其他强度(P2强度(所有养护时间)相比,抗压强度值最高(130.3,147.1和174 MPa)。虽然增加固化时间和固化强度对正畸胶粘剂的粘结强度和抗压强度有积极的影响,但在固化强度为2300 mW/cm2时,可以建议将正畸胶粘剂的固化时间缩短到1秒。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.40
自引率
0.00%
发文量
23
审稿时长
25 weeks
期刊介绍: Journal of Dental Research Dental Clinics Dental Prospects (JODDD) is a Platinum* Open Access, peer-reviewed quarterly indexed journal that publishes articles of basic, clinical, and prospective nature in all areas of dentistry and oral health.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信