Step-by-Step Approach to Build Multiple Reaction Monitoring (MRM) Profiling Instrument Acquisition Methods for Class-based Lipid Exploratory Analysis by Mass Spectrometry.
Leriana G Reis, Theresa M Casey, Tiago J P Sobreira, Bruce R Cooper, Christina R Ferreira
{"title":"Step-by-Step Approach to Build Multiple Reaction Monitoring (MRM) Profiling Instrument Acquisition Methods for Class-based Lipid Exploratory Analysis by Mass Spectrometry.","authors":"Leriana G Reis, Theresa M Casey, Tiago J P Sobreira, Bruce R Cooper, Christina R Ferreira","doi":"10.7171/3fc1f5fe.1972c438","DOIUrl":null,"url":null,"abstract":"<p><p>Multiple reaction monitoring (MRM) profiling is a strategy for the exploratory analysis of small molecules and lipids by direct sample injection, ie, without the use of chromatographic separation. It is based on instrument methods that comprise a list of ion transitions (MRMs), in which the precursor ion is the expected ionized <i>m/z</i> of the lipid at its species level, ie, the description of lipid class and number of carbon and double bonds in the fatty acid chain(s), and the product ion is a fragment expected for the lipid class or for the fatty acid neutral loss. The Lipid Maps database is expanding constantly, and therefore the MRM-profiling methods associated with this database need to be continuously updated. Here, we provide a comprehensive overview and the key references for the MRM-profiling methodology and workflow, followed by a step-by-step approach to build MRM-profiling instrument acquisition methods for class-based lipid exploratory analysis based on the Lipid Maps database. The detailed workflow includes (1) importing the list of lipids from the database; (2) for a given class, combining isomeric lipids described at full structural level into 1 entry to obtain the neutral mass at species level; (3) attributing the standard Lipid Maps abbreviated nomenclature for the lipid at its species level; (4) predicting the ionized precursor ions; and (5) adding the expected product ion. We also describe how to simulate the precursor ion for the suspect screening of modified lipids using lipid oxidation and their expected product ions as an example. After determining the MRMs, information about collision energy, dwell time, and other instrument parameters are added to finalize the acquisition method. As an example of final method output, we describe the format for Agilent MassHunter v.B.06 and provide the parameters in which optimization can be performed by lipid class using one or more lipid standards.</p>","PeriodicalId":39617,"journal":{"name":"Journal of Biomolecular Techniques","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10332339/pdf/jbt-34-2-1javo5lz.pdf","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomolecular Techniques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7171/3fc1f5fe.1972c438","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 2
Abstract
Multiple reaction monitoring (MRM) profiling is a strategy for the exploratory analysis of small molecules and lipids by direct sample injection, ie, without the use of chromatographic separation. It is based on instrument methods that comprise a list of ion transitions (MRMs), in which the precursor ion is the expected ionized m/z of the lipid at its species level, ie, the description of lipid class and number of carbon and double bonds in the fatty acid chain(s), and the product ion is a fragment expected for the lipid class or for the fatty acid neutral loss. The Lipid Maps database is expanding constantly, and therefore the MRM-profiling methods associated with this database need to be continuously updated. Here, we provide a comprehensive overview and the key references for the MRM-profiling methodology and workflow, followed by a step-by-step approach to build MRM-profiling instrument acquisition methods for class-based lipid exploratory analysis based on the Lipid Maps database. The detailed workflow includes (1) importing the list of lipids from the database; (2) for a given class, combining isomeric lipids described at full structural level into 1 entry to obtain the neutral mass at species level; (3) attributing the standard Lipid Maps abbreviated nomenclature for the lipid at its species level; (4) predicting the ionized precursor ions; and (5) adding the expected product ion. We also describe how to simulate the precursor ion for the suspect screening of modified lipids using lipid oxidation and their expected product ions as an example. After determining the MRMs, information about collision energy, dwell time, and other instrument parameters are added to finalize the acquisition method. As an example of final method output, we describe the format for Agilent MassHunter v.B.06 and provide the parameters in which optimization can be performed by lipid class using one or more lipid standards.
期刊介绍:
The Journal of Biomolecular Techniques is a peer-reviewed publication issued five times a year by the Association of Biomolecular Resource Facilities. The Journal was established to promote the central role biotechnology plays in contemporary research activities, to disseminate information among biomolecular resource facilities, and to communicate the biotechnology research conducted by the Association’s Research Groups and members, as well as other investigators.