{"title":"Vertebral artery sparing volumetric modulated arc therapy in nasopharyngeal carcinoma","authors":"Szu-Huai Lu MS ,&nbsp;Hao-Ting Lan MS ,&nbsp;Yi-Chun Tsai MS ,&nbsp;Ya-Fang Chen MD ,&nbsp;Shih-Fan Lai MD ,&nbsp;Hsiang-Kuang Liang MD ,&nbsp;Bing-Shen Huang MD ,&nbsp;Wan-Yu Chen MD, PhD ,&nbsp;Chun-Wei Wang MD, PhD","doi":"10.1016/j.meddos.2023.08.004","DOIUrl":null,"url":null,"abstract":"<div><p><span><span><span>Vascular stenosis is a late radiation complication that develops in long-term survivors of nasopharyngeal carcinoma. </span>Vertebral arteries<span> (VAs) are major vessels responsible for posterior circulation. In this study, we evaluated the feasibility of VA-sparing volumetric modulated arc therapy (VMAT) techniques. A total of 20 patients with nasopharyngeal carcinoma treated by a </span></span>TrueBeam linear accelerator were enrolled in this study. The original VMAT plan was designed without the contouring of VAs as organs at risk (OARs). The same image set of the original VMAT plan was used to contour the VAs for each patient. A new VA-sparing VMAT plan was developed by avoiding VAs as OARs. Finally, a paired t-test was used to compare the dosimetric differences. The VA-sparing VMAT plan had similar target coverage and dose to those of other OARs. The VA-sparing plan yielded a significantly low VA dose from 53 to 40 Gy, with V35Gy changing from 97% to 56%, V50Gy changing from 67% to 35%, and V63Gy changing from 15% to approximately 7%–10% (</span><em>p</em> &lt; 0.001 for all comparisons). VAs should be correctly identified as OARs. Photon VMAT with VA sparing can help substantially decrease the VA dose.</p></div>","PeriodicalId":49837,"journal":{"name":"Medical Dosimetry","volume":"48 4","pages":"Pages 304-311"},"PeriodicalIF":1.1000,"publicationDate":"2023-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Dosimetry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0958394723000699","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Vascular stenosis is a late radiation complication that develops in long-term survivors of nasopharyngeal carcinoma. Vertebral arteries (VAs) are major vessels responsible for posterior circulation. In this study, we evaluated the feasibility of VA-sparing volumetric modulated arc therapy (VMAT) techniques. A total of 20 patients with nasopharyngeal carcinoma treated by a TrueBeam linear accelerator were enrolled in this study. The original VMAT plan was designed without the contouring of VAs as organs at risk (OARs). The same image set of the original VMAT plan was used to contour the VAs for each patient. A new VA-sparing VMAT plan was developed by avoiding VAs as OARs. Finally, a paired t-test was used to compare the dosimetric differences. The VA-sparing VMAT plan had similar target coverage and dose to those of other OARs. The VA-sparing plan yielded a significantly low VA dose from 53 to 40 Gy, with V35Gy changing from 97% to 56%, V50Gy changing from 67% to 35%, and V63Gy changing from 15% to approximately 7%–10% (p < 0.001 for all comparisons). VAs should be correctly identified as OARs. Photon VMAT with VA sparing can help substantially decrease the VA dose.

保留椎动脉体积调制电弧治疗鼻咽癌。
血管狭窄是一种晚期放疗并发症,发生在鼻咽癌的长期幸存者身上。椎动脉(VA)是负责后循环的主要血管。在本研究中,我们评估了保留VA体积调制电弧治疗(VMAT)技术的可行性。本研究共招募了20名使用TrueBeam线性加速器治疗的鼻咽癌患者。最初的VMAT计划是在没有将VA作为危险器官(OAR)的情况下设计的。使用原始VMAT计划的相同图像集来对每个患者的VA进行轮廓绘制。通过避免将VA作为OAR,制定了一项新的VA备用VMAT计划。最后,使用配对t检验来比较剂量测定差异。保留VA的VMAT计划与其他OAR的目标覆盖率和剂量相似。VA保留计划产生的VA剂量从53到40Gy显著较低,V35Gy从97%变为56%,V50Gy从67%变为35%,V63Gy从15%变为约7%-10%(所有比较均<0.001)。VA应正确识别为OAR。保留VA的光子VMAT可以帮助显著降低VA剂量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical Dosimetry
Medical Dosimetry 医学-核医学
CiteScore
2.40
自引率
0.00%
发文量
51
审稿时长
34 days
期刊介绍: Medical Dosimetry, the official journal of the American Association of Medical Dosimetrists, is the key source of information on new developments for the medical dosimetrist. Practical and comprehensive in coverage, the journal features original contributions and review articles by medical dosimetrists, oncologists, physicists, and radiation therapy technologists on clinical applications and techniques of external beam, interstitial, intracavitary and intraluminal irradiation in cancer management. Articles dealing primarily with physics will be reviewed by a specially appointed team of experts in the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信