Rebecca R Rafla, Mark A Saxen, Juan F Yepes, James E Jones, LaQuia A Vinson
{"title":"Comparison of Oropharyngeal Oxygen Pooling and Suctioning During Intubated and Nonintubated Dental Office-Based Anesthesia.","authors":"Rebecca R Rafla, Mark A Saxen, Juan F Yepes, James E Jones, LaQuia A Vinson","doi":"10.2344/anpr-70-01-02","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The risk of a spontaneous surgical fire increases as oxygen concentrations surrounding the surgical site rise above the normal atmospheric level of 21%. Previously published in vitro findings imply this phenomenon (termed oxygen pooling) occurs during dental procedures under sedation and general anesthesia; however, it has not been clinically documented.</p><p><strong>Methods: </strong>Thirty-one children classified as American Society of Anesthesiologists I and II between 2 and 6 years of age undergoing office-based general anesthesia for complete dental rehabilitation were monitored for intraoral ambient oxygen concentration, end-tidal CO2, and respiratory rate changes immediately following nasotracheal intubation or insertion of nasopharyngeal airways, followed by high-speed suctioning of the oral cavity during simulated dental treatment.</p><p><strong>Results: </strong>Mean ambient intraoral oxygen concentrations ranging from 46.9% to 72.1%, levels consistent with oxygen pooling, occurred in the nasopharyngeal airway group prior to the introduction of high-speed oral suctioning. However, 1 minute of suctioning reversed the oxygen pooling to 31.2%. Oropharyngeal ambient oxygen concentrations in patients with uncuffed endotracheal tubes ranged from 24.1% to 26.6% prior to high-speed suctioning, which reversed the pooling to 21.1% after 1 minute.</p><p><strong>Conclusion: </strong>This study demonstrated significant oxygen pooling with nasopharyngeal airway use before and after high-speed suctioning. Uncuffed endotracheal intubation showed minimal pooling, which was reversed to room air ambient oxygen concentrations after 1 minute of suctioning.</p>","PeriodicalId":7818,"journal":{"name":"Anesthesia progress","volume":"70 1","pages":"3-8"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10069532/pdf/i1878-7177-70-1-3.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anesthesia progress","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2344/anpr-70-01-02","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: The risk of a spontaneous surgical fire increases as oxygen concentrations surrounding the surgical site rise above the normal atmospheric level of 21%. Previously published in vitro findings imply this phenomenon (termed oxygen pooling) occurs during dental procedures under sedation and general anesthesia; however, it has not been clinically documented.
Methods: Thirty-one children classified as American Society of Anesthesiologists I and II between 2 and 6 years of age undergoing office-based general anesthesia for complete dental rehabilitation were monitored for intraoral ambient oxygen concentration, end-tidal CO2, and respiratory rate changes immediately following nasotracheal intubation or insertion of nasopharyngeal airways, followed by high-speed suctioning of the oral cavity during simulated dental treatment.
Results: Mean ambient intraoral oxygen concentrations ranging from 46.9% to 72.1%, levels consistent with oxygen pooling, occurred in the nasopharyngeal airway group prior to the introduction of high-speed oral suctioning. However, 1 minute of suctioning reversed the oxygen pooling to 31.2%. Oropharyngeal ambient oxygen concentrations in patients with uncuffed endotracheal tubes ranged from 24.1% to 26.6% prior to high-speed suctioning, which reversed the pooling to 21.1% after 1 minute.
Conclusion: This study demonstrated significant oxygen pooling with nasopharyngeal airway use before and after high-speed suctioning. Uncuffed endotracheal intubation showed minimal pooling, which was reversed to room air ambient oxygen concentrations after 1 minute of suctioning.
期刊介绍:
Anesthesia Progress is a peer-reviewed journal and the official publication of the American Dental Society of Anesthesiology. The journal is dedicated to providing a better understanding of the advances being made in the art and science of pain and anxiety control in dentistry.