Concordance and reproducibility in the location of reference points for a volumetric craniofacial analysis: Cross-sectional study.

Q4 Dentistry
Natali Romero-Tapiero, Andrés Giraldo-Mejía, Adriana Herrera-Rubio, Juan Fernando Aristizábal-Pérez
{"title":"Concordance and reproducibility in the location of reference points for a volumetric craniofacial analysis: Cross-sectional study.","authors":"Natali Romero-Tapiero,&nbsp;Andrés Giraldo-Mejía,&nbsp;Adriana Herrera-Rubio,&nbsp;Juan Fernando Aristizábal-Pérez","doi":"10.34172/joddd.2023.37025","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Considering the limitations of visualization that occur even with the use of radiographs, the cone beam computed tomography (CBCT) becomes more attractive to diagnose and propose an assertive treatment plan. This study aimed to evaluate intra and interobserver reproducibility, and concordance of 31 reference points we described considering visualization tools and the three planes of space in a bimaxillary CBCT.</p><p><strong>Methods: </strong>Three observers located in triplicate the 31 reference points in the CBCT of six healthy patients. Friedman test was used to compare intraobserver paired samples, and interobserver concordance was determined by the intraclass correlation coefficient (ICC) with ranges>0.75 (excellent), between 0.60 and 0.74 (good), between 0.40 and 0.59 (sufficient) and<0.40 (poor). The <i>P</i> value was set at<0.05.</p><p><strong>Results: </strong>A high ICC (>0.75%) was obtained by comparing the x, y, and z values at the location of landmark points. Excellent ICC>0.75 was for 81.7% and poor<0.40 was 7.5% in the interobserver evaluation. Data showed that 25 points had excellent concordance on the x-plane, 25 on the y-plane, and 26 on the z-plane (0.75%).</p><p><strong>Conclusion: </strong>Intraobserver concordance analysis indicated that location of anatomical reference points on bimaxillary CBCT is performed with great reproducibility by interpreting their location with a clear description in the three planes of space. Complexity of achieving a good precision degree in the manual marking of reference points caused by convexities of the anatomical structures involved, might explain the variability found. The systematized location of the reference points would contribute to reduce such variability.</p>","PeriodicalId":15599,"journal":{"name":"Journal of Dental Research, Dental Clinics, Dental Prospects","volume":"17 2","pages":"87-95"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10462468/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dental Research, Dental Clinics, Dental Prospects","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/joddd.2023.37025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Considering the limitations of visualization that occur even with the use of radiographs, the cone beam computed tomography (CBCT) becomes more attractive to diagnose and propose an assertive treatment plan. This study aimed to evaluate intra and interobserver reproducibility, and concordance of 31 reference points we described considering visualization tools and the three planes of space in a bimaxillary CBCT.

Methods: Three observers located in triplicate the 31 reference points in the CBCT of six healthy patients. Friedman test was used to compare intraobserver paired samples, and interobserver concordance was determined by the intraclass correlation coefficient (ICC) with ranges>0.75 (excellent), between 0.60 and 0.74 (good), between 0.40 and 0.59 (sufficient) and<0.40 (poor). The P value was set at<0.05.

Results: A high ICC (>0.75%) was obtained by comparing the x, y, and z values at the location of landmark points. Excellent ICC>0.75 was for 81.7% and poor<0.40 was 7.5% in the interobserver evaluation. Data showed that 25 points had excellent concordance on the x-plane, 25 on the y-plane, and 26 on the z-plane (0.75%).

Conclusion: Intraobserver concordance analysis indicated that location of anatomical reference points on bimaxillary CBCT is performed with great reproducibility by interpreting their location with a clear description in the three planes of space. Complexity of achieving a good precision degree in the manual marking of reference points caused by convexities of the anatomical structures involved, might explain the variability found. The systematized location of the reference points would contribute to reduce such variability.

Abstract Image

颅面体积分析参考点位置的一致性和可重复性:横断面研究。
背景:考虑到即使使用x线片也存在可视化的局限性,锥束计算机断层扫描(CBCT)在诊断和提出自信的治疗方案方面变得更有吸引力。本研究旨在评估双颌CBCT中31个参考点的再现性和一致性,这些参考点考虑了可视化工具和三个空间平面。方法:对6例健康患者的31个CBCT参考点进行三组观察。使用Friedman检验比较观察者内配对样本,观察者间一致性由类内相关系数(ICC)确定,其范围>0.75(优秀),0.60 - 0.74(良好),0.40 - 0.59(充分),p值设为。结果:通过比较地标点位置的x, y和z值获得较高的ICC(>0.75%)。结论:观察者内一致性分析表明,双上颌CBCT解剖参考点的位置在三个空间平面上有清晰的描述,可以解释其位置,具有很高的再现性。由于所涉及的解剖结构的凹凸性,在手工标记参考点时要达到良好的精度程度是很复杂的,这可能解释了所发现的可变性。参考点的系统化位置将有助于减少这种变异性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.40
自引率
0.00%
发文量
23
审稿时长
25 weeks
期刊介绍: Journal of Dental Research Dental Clinics Dental Prospects (JODDD) is a Platinum* Open Access, peer-reviewed quarterly indexed journal that publishes articles of basic, clinical, and prospective nature in all areas of dentistry and oral health.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信