Comparison of Medical Treatment Efficiency With Shear Wave Elastography Values of Thrombus in Patients With Lower Extremity Deep Vein Thrombosis.

IF 0.7 4区 医学 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Suat İnce, Mesut Özgokçe, Sercan Özkaçmaz, İlyas Dündar, Ensar Türko, Veysel A Ayyıldız, Cemil Göya
{"title":"Comparison of Medical Treatment Efficiency With Shear Wave Elastography Values of Thrombus in Patients With Lower Extremity Deep Vein Thrombosis.","authors":"Suat İnce,&nbsp;Mesut Özgokçe,&nbsp;Sercan Özkaçmaz,&nbsp;İlyas Dündar,&nbsp;Ensar Türko,&nbsp;Veysel A Ayyıldız,&nbsp;Cemil Göya","doi":"10.1097/RUQ.0000000000000643","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>In lower-extremity deep vein thrombosis (DVT), thrombus age is essential for successful treatment. The aim of our study was to compare the shear wave elastography (SWE) values measured before treatment and achieved lumen patency after treatment in lower-extremity DVT patients with total occlusion. Patients diagnosed with DVT in the acute-subacute stage (<4 week) with total thrombosis in lower extremity were included in this prospective study. Shear wave elastography measurements were performed where the thrombus was most prominent and homogeneous. To evaluate patient response to treatment, lumen patency (partial [>25%] or total recanalization) was examined using color Doppler imaging in the first and third months posttreatment. Shear wave elastography values with and without patency were compared using an independent t test. Among 75 patients in this study, at the first-month color Doppler imaging examination, the SWE values were 1.77 ± 0.49 (1.09-3.03) m/s in patients who achieved lumen patency (n = 42) and 2.21 ± 0.54 (1.24-3.36) m/s in those who did not show lumen patency (n = 33). The difference between the groups' mean elastography value was statistically significant ( P < 0.001). At the third-month examination, the SWE values were 1.76 ± 0.46 (1.09-3.03) m/s in patients with lumen patency (n = 55) and 2.52 ± 0.48 (1.74-3.36) in patients without lumen patency (n = 20). The difference between the 2 groups' mean elastography value was statistically significant ( P < 0.001). We concluded that it is more difficult to achieve lumen patency in veins occluded by thrombus with higher elasto values, and endovascular interventional procedures should be considered during the initial treatment of high SWE value thrombosis.</p>","PeriodicalId":49116,"journal":{"name":"Ultrasound Quarterly","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound Quarterly","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RUQ.0000000000000643","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract: In lower-extremity deep vein thrombosis (DVT), thrombus age is essential for successful treatment. The aim of our study was to compare the shear wave elastography (SWE) values measured before treatment and achieved lumen patency after treatment in lower-extremity DVT patients with total occlusion. Patients diagnosed with DVT in the acute-subacute stage (<4 week) with total thrombosis in lower extremity were included in this prospective study. Shear wave elastography measurements were performed where the thrombus was most prominent and homogeneous. To evaluate patient response to treatment, lumen patency (partial [>25%] or total recanalization) was examined using color Doppler imaging in the first and third months posttreatment. Shear wave elastography values with and without patency were compared using an independent t test. Among 75 patients in this study, at the first-month color Doppler imaging examination, the SWE values were 1.77 ± 0.49 (1.09-3.03) m/s in patients who achieved lumen patency (n = 42) and 2.21 ± 0.54 (1.24-3.36) m/s in those who did not show lumen patency (n = 33). The difference between the groups' mean elastography value was statistically significant ( P < 0.001). At the third-month examination, the SWE values were 1.76 ± 0.46 (1.09-3.03) m/s in patients with lumen patency (n = 55) and 2.52 ± 0.48 (1.74-3.36) in patients without lumen patency (n = 20). The difference between the 2 groups' mean elastography value was statistically significant ( P < 0.001). We concluded that it is more difficult to achieve lumen patency in veins occluded by thrombus with higher elasto values, and endovascular interventional procedures should be considered during the initial treatment of high SWE value thrombosis.

下肢深静脉血栓形成患者血栓剪切波弹性成像治疗效果的比较。
摘要:下肢深静脉血栓形成(DVT),血栓年龄是治疗成功的关键。我们研究的目的是比较完全闭塞的下肢深静脉血栓形成患者在治疗前测量的剪切波弹性成像(SWE)值和治疗后获得的管腔通畅性。在治疗后的第一个月和第三个月,使用彩色多普勒成像对诊断为急性亚急性期(25%]或完全再通)DVT的患者进行检查。使用独立t检验比较有无通畅的剪切波弹性成像值。在本研究的75名患者中,在第一个月的彩色多普勒成像检查中,实现管腔通畅的患者(n=42)的SWE值为1.77±0.49(1.09-3.03)m/s,未实现管腔通畅(n=33)的患者的SWE为2.21±0.54(1.24-3.36)m/s。两组的平均弹性成像值之间的差异具有统计学意义(P<0.001)。在第三个月的检查中,有管腔通畅的患者(n=55)的SWE值为1.76±0.46(1.09-3.03)m/s,无管腔通畅的病例(n=20)为2.52±0.48(1.74-3.36)。两组的平均弹性成像值之间的差异具有统计学意义(P<0.001)。我们得出的结论是,在弹性值较高的血栓闭塞静脉中,更难实现管腔通畅,在高SWE值血栓形成的初始治疗过程中应考虑血管内介入程序。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Ultrasound Quarterly
Ultrasound Quarterly RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.50
自引率
7.70%
发文量
105
审稿时长
>12 weeks
期刊介绍: Ultrasound Quarterly provides coverage of the newest, most sophisticated ultrasound techniques as well as in-depth analysis of important developments in this dynamic field. The journal publishes reviews of a wide variety of topics including trans-vaginal ultrasonography, detection of fetal anomalies, color Doppler flow imaging, pediatric ultrasonography, and breast sonography. Official Journal of the Society of Radiologists in Ultrasound
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信