{"title":"Added value of early-phase SPECT over planar acquisition in bone imaging.","authors":"Nicolas Icard, Jules Zhang-Yin, David Morland","doi":"10.23736/S1824-4785.23.03523-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The aim of this study is to evaluate the added value of early bone single photon emission computed tomography (SPECT) by comparison to pseudoplanar imaging.</p><p><strong>Methods: </strong>Fifty patients were retrospectively included from 3 centers. Reading sessions were organized using: late-phase acquisition alone; early SPECT and late-phase acquisition; early pseudoplanar and late-phase acquisition. The comparison between early SPECT and MIP was performed using a McNemar Test. Patients for whom early SPECT had provided additional information were also compared with patients for whom early SPECT had not.</p><p><strong>Results: </strong>Fifty patients were included. Early SPECT was superior to pseudoplanar MIP in 10/50 patients (20.0%, P=0.044). No significant difference was found between this group and the remainder. Early SPECT changed the diagnosis established from late-phase imaging in 21/50 patients.</p><p><strong>Conclusions: </strong>Early SPECT is a promising tool in bone imaging and change the diagnosis in one fifth of the cases by comparison to pseudoplanar imaging.</p>","PeriodicalId":23069,"journal":{"name":"The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of...","volume":"67 3","pages":"202-205"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of...","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23736/S1824-4785.23.03523-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The aim of this study is to evaluate the added value of early bone single photon emission computed tomography (SPECT) by comparison to pseudoplanar imaging.
Methods: Fifty patients were retrospectively included from 3 centers. Reading sessions were organized using: late-phase acquisition alone; early SPECT and late-phase acquisition; early pseudoplanar and late-phase acquisition. The comparison between early SPECT and MIP was performed using a McNemar Test. Patients for whom early SPECT had provided additional information were also compared with patients for whom early SPECT had not.
Results: Fifty patients were included. Early SPECT was superior to pseudoplanar MIP in 10/50 patients (20.0%, P=0.044). No significant difference was found between this group and the remainder. Early SPECT changed the diagnosis established from late-phase imaging in 21/50 patients.
Conclusions: Early SPECT is a promising tool in bone imaging and change the diagnosis in one fifth of the cases by comparison to pseudoplanar imaging.