Utilising 3D-printed ex vivo biomimetics to improve open reduction and internal fixation (ORIF) simulation training for hand fractures.

IF 0.6 Q4 SURGERY
Theodora Papavasiliou, Gemma Batten, Oliver Bloom, Jeffrey C Y Chan, Charles J Bain, Lauren Uppal
{"title":"Utilising 3D-printed ex vivo biomimetics to improve open reduction and internal fixation (ORIF) simulation training for hand fractures.","authors":"Theodora Papavasiliou,&nbsp;Gemma Batten,&nbsp;Oliver Bloom,&nbsp;Jeffrey C Y Chan,&nbsp;Charles J Bain,&nbsp;Lauren Uppal","doi":"10.1007/s00238-023-02062-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Surgery for hand trauma accounts for a significant proportion of the plastic surgery training curriculum. The aim of this article is to create a standardised simulation training module for hand fracture fixation on open reduction and internal fixation (ORIF) techniques for residents in order to create a standardised hand-training framework that universally hones their skill and prepares them for their first encounter in a clinical setting.</p><p><strong>Methods: </strong>A step-ladder approach training using three-dimensional (3D)-printed ex vivo hand biomimetics was employed on a cohort of 15 plastic surgery residents (<i>n</i> = 15). Assessment of skills using a score system (global rating scale) was performed in the beginning and the end of the module by hand experts in our unit.</p><p><strong>Results: </strong>The overall average score of the cohort pre- and post-assessment were 22.08/50 (44.16%) and 41.54/50 (83.08%) respectively. Significant (<i>p</i> < 0.01) difference of improvement of skills was noted on all trainees. All trainees confirmed that the simulated models provided in this module were akin to the patient scenario and noted that it helped them improve their skills with regards to ORIF techniques including improvement of their understanding of the 3D bone topography.</p><p><strong>Conclusion: </strong>We demonstrate a standardised simulation training framework that employs 3D-printed ex vivo hand biomimetics proven to improve the skills of residents and which paves the way to more universal, standardised and validated training across hand surgery. This is, to our knowledge, the first standardised method of simulated training on such hand-surgical cases.Level of Evidence: Not ratable.</p>","PeriodicalId":12054,"journal":{"name":"European Journal of Plastic Surgery","volume":" ","pages":"1-7"},"PeriodicalIF":0.6000,"publicationDate":"2023-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10116095/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Plastic Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s00238-023-02062-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Surgery for hand trauma accounts for a significant proportion of the plastic surgery training curriculum. The aim of this article is to create a standardised simulation training module for hand fracture fixation on open reduction and internal fixation (ORIF) techniques for residents in order to create a standardised hand-training framework that universally hones their skill and prepares them for their first encounter in a clinical setting.

Methods: A step-ladder approach training using three-dimensional (3D)-printed ex vivo hand biomimetics was employed on a cohort of 15 plastic surgery residents (n = 15). Assessment of skills using a score system (global rating scale) was performed in the beginning and the end of the module by hand experts in our unit.

Results: The overall average score of the cohort pre- and post-assessment were 22.08/50 (44.16%) and 41.54/50 (83.08%) respectively. Significant (p < 0.01) difference of improvement of skills was noted on all trainees. All trainees confirmed that the simulated models provided in this module were akin to the patient scenario and noted that it helped them improve their skills with regards to ORIF techniques including improvement of their understanding of the 3D bone topography.

Conclusion: We demonstrate a standardised simulation training framework that employs 3D-printed ex vivo hand biomimetics proven to improve the skills of residents and which paves the way to more universal, standardised and validated training across hand surgery. This is, to our knowledge, the first standardised method of simulated training on such hand-surgical cases.Level of Evidence: Not ratable.

利用3D打印的离体仿生技术改进手部骨折的切开复位和内固定(ORIF)模拟训练。
背景:手外伤手术在整形外科培训课程中占很大比例。本文的目的是为住院医师创建一个标准化的模拟训练模块,用于开放复位和内固定(ORIF)技术的手部骨折固定,以创建一个通用的手部训练框架,使他们的技能得到普遍提高,并为他们在临床环境中的首次接触做好准备。方法:对15名整形外科住院医师(n = 15) 。本单元的手工专家在模块开始和结束时使用评分系统(全球评分量表)对技能进行了评估。结果:队列评估前和评估后的总体平均得分分别为22.08/50(44.16%)和41.54/50(83.08%)。显著(p 结论:我们展示了一个标准化的模拟训练框架,该框架采用了3D打印的离体手部仿生技术,经证明可以提高住院医师的技能,并为手部手术中更通用、标准化和验证的训练铺平了道路。据我们所知,这是第一种针对此类手外科病例进行模拟训练的标准化方法。证据级别:不可评级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.10
自引率
0.00%
发文量
93
期刊介绍: Europe has always been an area of dynamic development in plastic surgery. Its great strength has been the lack of uniformity of this development due to differing cultures, different traditions, and differing medical and surgical philosophies. Over the recent years, these changes have been even more striking and rapid. The European Journal of Plastic Surgery creates a focal point for the input of new advances in clinical techniques and in research. It thus becomes an educational vehicle. In addition to this, the journal provides information on what is going on elsewhere in the world, and it is also willing to accept contributions from outside of Europe. Fields of interest include general plastic and reconstructive surgery, head and neck surgery, aesthetic and craniofacial surgery, hand surgery, microsurgery, treatment of bones, trauma, burn management and basic research related to all aspects of plastic surgery.Submitted articles are first evaluated by the Editor in Chief and if judged appropriate, are peer-reviewed by at least two selected experts. Reviewers may be plastic surgeons or other surgical/ medical specialists with expertise in specific areas of research. Manuscripts provisionally accepted for publication may be returned to the author for corrections or clarifications, in response to suggestions by the Editorial Board or external reviewers, prior to final acceptance.  Online submission and peer review for rapid online publication are offered through the Editorial Manager System. The system creates a PDF version of the submitted article for peer review, revision and proofing. All correspondence, including the request for revisions and final decision, is managed by e-mail. Authors are guided step by step through the full process and are kept up to date on the article’s progress at every stage.  Manuscripts submitted for publication must contain a statement to the effect that all human studies have been reviewed by the appropriate ethics committee and have therefore been performed in accordance with the ethical standards laid down in an appropriate version of the 1964 Declaration of Helsinki. It should also be stated clearly in the text that all persons gave their informed consent prior to their inclusion in the study. Details that might disclose the identity of the subjects under study should be omitted.Reports of animal experiments must state that the ''Principles of laboratory animal care'' (NIH publication No. 86-23, revised in 1985) were followed, as well as specific national laws (e.g. the current version of the German Law on the Protection of Animals) where applicable.Acknowledgments of people, grants, funds, etc. should be placed in a separate section before the reference list. The names of funding organizations should be written in full. Authors are also required to disclose any relationships with public or private commercial or noncommercial entities, any institutional affiliations, or any personal associations that might pose a conflict of interest.The Editors reserve the right to reject manuscripts that do not comply with the above-mentioned requirements. The author will be held responsible for false statements or for failure to fulfill the above-mentioned requirements.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信