Two-Year Results of a First-In-Human Study in Patients Surgically Implanted With a Bioprosthetic Venous Valve, the VenoValve in Patients With Severe Chronic Venous Insufficiency.
Jorge H Ulloa, Sebastian Cifuentes, Valentin Figueroa, Marc Glickman
{"title":"Two-Year Results of a First-In-Human Study in Patients Surgically Implanted With a Bioprosthetic Venous Valve, the VenoValve in Patients With Severe Chronic Venous Insufficiency.","authors":"Jorge H Ulloa, Sebastian Cifuentes, Valentin Figueroa, Marc Glickman","doi":"10.1177/15385744231155327","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Two-year follow-up results from a first-in-human study of patients implanted with the VenoValve are evaluated for supporting the long-term clinical safety and performance of the device.</p><p><strong>Background: </strong>Chronic Venous Insufficiency (CVI) involves improper functioning of lower limb vein valves and inability of these valves to move blood back towards the heart. CVI symptoms include swelling, varicose veins, pain, and leg ulcers. Currently, there is no cure for this condition and treatment options are limited. This study provides 2-year outcomes for 8 patients who were implanted with the bioprosthetic VenoValve for treating severe CVI with deep venous reflux measured at the mid-popliteal vein. The 6-month and 1-year results were previously published.</p><p><strong>Methods: </strong>Eleven patients with C5 & C6 CVI were implanted with VenoValve into the midthigh femoral vein and followed for 2 years. Assessed clinical outcomes include device-related adverse events, reflux time, disease severity, and pain scores.</p><p><strong>Results: </strong>All 11 implant procedures were successful. Two-year follow-up data was obtained for 8 subjects: 1 patient died of non-device related causes, 1 was lost to follow-up, and 1 refused to follow-up due to the COVID-19 pandemic. No device-related adverse events occurred between the first and second years of follow-up. Reported 2-year clinical performance outcomes included significant decreases in mean reflux times of the mid-popliteal vein (61%), and significant improvements in mean scores for disease severity rVCSS (56%) and VAS pain (87%).</p><p><strong>Conclusions: </strong>Results from this study support long-term safety and effectiveness of the VenoValve for improving CVI severity by reducing reflux and thereby venous pressures in the lower extremities. With limited treatments for valvular incompetence involved in severe, deep venous CVI, the device may be considered as a novel therapy. A pivotal trial in the United States is currently being conducted to assess the device in a larger number of patients.</p>","PeriodicalId":23530,"journal":{"name":"Vascular and Endovascular Surgery","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vascular and Endovascular Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15385744231155327","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: Two-year follow-up results from a first-in-human study of patients implanted with the VenoValve are evaluated for supporting the long-term clinical safety and performance of the device.
Background: Chronic Venous Insufficiency (CVI) involves improper functioning of lower limb vein valves and inability of these valves to move blood back towards the heart. CVI symptoms include swelling, varicose veins, pain, and leg ulcers. Currently, there is no cure for this condition and treatment options are limited. This study provides 2-year outcomes for 8 patients who were implanted with the bioprosthetic VenoValve for treating severe CVI with deep venous reflux measured at the mid-popliteal vein. The 6-month and 1-year results were previously published.
Methods: Eleven patients with C5 & C6 CVI were implanted with VenoValve into the midthigh femoral vein and followed for 2 years. Assessed clinical outcomes include device-related adverse events, reflux time, disease severity, and pain scores.
Results: All 11 implant procedures were successful. Two-year follow-up data was obtained for 8 subjects: 1 patient died of non-device related causes, 1 was lost to follow-up, and 1 refused to follow-up due to the COVID-19 pandemic. No device-related adverse events occurred between the first and second years of follow-up. Reported 2-year clinical performance outcomes included significant decreases in mean reflux times of the mid-popliteal vein (61%), and significant improvements in mean scores for disease severity rVCSS (56%) and VAS pain (87%).
Conclusions: Results from this study support long-term safety and effectiveness of the VenoValve for improving CVI severity by reducing reflux and thereby venous pressures in the lower extremities. With limited treatments for valvular incompetence involved in severe, deep venous CVI, the device may be considered as a novel therapy. A pivotal trial in the United States is currently being conducted to assess the device in a larger number of patients.
期刊介绍:
Vascular and Endovascular Surgery (VES) is a peer-reviewed journal that publishes information to guide vascular specialists in endovascular, surgical, and medical treatment of vascular disease. VES contains original scientific articles on vascular intervention, including new endovascular therapies for peripheral artery, aneurysm, carotid, and venous conditions. This journal is a member of the Committee on Publication Ethics (COPE).