Jörg D Ulrich, Paul Rechberger, Jeannine Bachmann, Alexander Herner, Guido V Figura, Tobias Lahmer, Veit Phillip, Ulrich Mayr, Bernhard Haller, Moritz Jesinghaus, Roland M Schmid, Mohamed Abdelhafez, Christoph Schlag
{"title":"Efficacy and Safety of Cold Snare Polypectomy of Colorectal Polyps 10-15 mm with a Hybrid Snare: A Prospective Observational Pilot Study.","authors":"Jörg D Ulrich, Paul Rechberger, Jeannine Bachmann, Alexander Herner, Guido V Figura, Tobias Lahmer, Veit Phillip, Ulrich Mayr, Bernhard Haller, Moritz Jesinghaus, Roland M Schmid, Mohamed Abdelhafez, Christoph Schlag","doi":"10.1159/000530642","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Cold snare polypectomy (CSP) is a safe and effective procedure for small colorectal polyps ≤9 mm. There are only limited data regarding CSP of larger neoplastic lesions. This study evaluated the efficacy and safety of CSP for polyps between 10 and 15 mm in size.</p><p><strong>Methods: </strong>In this prospective single-arm observational pilot study, patients with a least one polyp 10-15 mm were included. These polyps were preferably removed by CSP using a dedicated hybrid snare. The primary outcome was the histological complete resection rate (CRR) determined by pathologically negative margins of the specimen and no neoplastic tissue obtained from biopsies of the resection site margin. Secondary outcomes were en bloc resection rate, failure of CSP, and incidence of adverse events.</p><p><strong>Results: </strong>A total of 61 neoplastic polyps were removed from 39 patients. Overall CRR was 80.3% (49/61). CSP was feasible in 78.7% (48/61) of polyps and the CRR in this group was 85.4% (41/48). When CSP failed (13/61; 21.3%), lesions were successfully resected by immediate HSP using the same snare with a CRR of 61.5% (8/13) in this group. One patient presented delayed hemorrhage after HSP of a polyp but successful hemostasis was achieved with two hemoclips. No other adverse events occurred. No recurrence was seen on follow-up colonoscopy in cases with incomplete resected polyps.</p><p><strong>Conclusion: </strong>CSP seems to be efficient and safe in removing colorectal polyps up to 15 mm. A hybrid snare seems to be particularly advantageous for these polyps as it allows immediate conversion to HSP if CSP might fail in larger polyps. This trial is registered at ClinicalTrials.gov (NCT04464837).</p>","PeriodicalId":11315,"journal":{"name":"Digestion","volume":" ","pages":"391-399"},"PeriodicalIF":3.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digestion","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000530642","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/16 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Cold snare polypectomy (CSP) is a safe and effective procedure for small colorectal polyps ≤9 mm. There are only limited data regarding CSP of larger neoplastic lesions. This study evaluated the efficacy and safety of CSP for polyps between 10 and 15 mm in size.
Methods: In this prospective single-arm observational pilot study, patients with a least one polyp 10-15 mm were included. These polyps were preferably removed by CSP using a dedicated hybrid snare. The primary outcome was the histological complete resection rate (CRR) determined by pathologically negative margins of the specimen and no neoplastic tissue obtained from biopsies of the resection site margin. Secondary outcomes were en bloc resection rate, failure of CSP, and incidence of adverse events.
Results: A total of 61 neoplastic polyps were removed from 39 patients. Overall CRR was 80.3% (49/61). CSP was feasible in 78.7% (48/61) of polyps and the CRR in this group was 85.4% (41/48). When CSP failed (13/61; 21.3%), lesions were successfully resected by immediate HSP using the same snare with a CRR of 61.5% (8/13) in this group. One patient presented delayed hemorrhage after HSP of a polyp but successful hemostasis was achieved with two hemoclips. No other adverse events occurred. No recurrence was seen on follow-up colonoscopy in cases with incomplete resected polyps.
Conclusion: CSP seems to be efficient and safe in removing colorectal polyps up to 15 mm. A hybrid snare seems to be particularly advantageous for these polyps as it allows immediate conversion to HSP if CSP might fail in larger polyps. This trial is registered at ClinicalTrials.gov (NCT04464837).
期刊介绍:
''Digestion'' concentrates on clinical research reports: in addition to editorials and reviews, the journal features sections on Stomach/Esophagus, Bowel, Neuro-Gastroenterology, Liver/Bile, Pancreas, Metabolism/Nutrition and Gastrointestinal Oncology. Papers cover physiology in humans, metabolic studies and clinical work on the etiology, diagnosis, and therapy of human diseases. It is thus especially cut out for gastroenterologists employed in hospitals and outpatient units. Moreover, the journal''s coverage of studies on the metabolism and effects of therapeutic drugs carries considerable value for clinicians and investigators beyond the immediate field of gastroenterology.