{"title":"经导管主动脉瓣置换术后的颈动脉僵硬度","authors":"Refik Kavsur, Christian Schaefer, Max Jonathan Stumpf, Marcel Weber, Atsushi Sugiura, Marc Ulrich Becher, Sebastian Zimmer, Georg Nickenig, Nadjib Schahab","doi":"10.1177/00033197231195647","DOIUrl":null,"url":null,"abstract":"<p><p>The present study aimed to analyze common carotid artery strain properties in patients (n = 59) with severe aortic valve stenosis who underwent transcatheter aortic valve replacement (TAVR). Arterial compliance of the common carotid artery was assessed by ultrasound speckle-tracking before and after TAVR. For sub-analysis the study cohort was divided according to aortic valve area <.75 cm<sup>2</sup> (n = 30) vs ≥.75 cm<sup>2</sup> (n = 29). Comparison of pre- and post-procedural strain variables showed an improvement in median radial velocity (<i>P</i> < .0001), radial displacement (<i>P</i> = .007), circumferential strain (<i>P</i> = .004), radial strain rate (<i>P</i> = .023), and circumferential strain rate (<i>P</i> < .0001), while the increase of radial strain showed a trend (<i>P</i> = .082). Analysis of aortic valve area revealed an inverse correlation between aortic valve area and the differences (post-procedural-pre-procedural values) for radial strain rate, and circumferential strain. Moreover, sub-analysis revealed that the increase of carotid strain variables before and after TAVR were more pronounced in the sub-group of aortic valve area .75 vs ≥.75 cm<sup>2</sup>. TAVR led to a reduction of arterial wall stiffness of the common carotid artery assessed by ultrasound speckle-tracking. The decrease of arterial wall stiffness after TAVR was more pronounced in more severe aortic valve stenosis.</p>","PeriodicalId":8264,"journal":{"name":"Angiology","volume":" ","pages":"985-991"},"PeriodicalIF":2.6000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Carotid Stiffness After Transcatheter Aortic Valve Replacement.\",\"authors\":\"Refik Kavsur, Christian Schaefer, Max Jonathan Stumpf, Marcel Weber, Atsushi Sugiura, Marc Ulrich Becher, Sebastian Zimmer, Georg Nickenig, Nadjib Schahab\",\"doi\":\"10.1177/00033197231195647\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The present study aimed to analyze common carotid artery strain properties in patients (n = 59) with severe aortic valve stenosis who underwent transcatheter aortic valve replacement (TAVR). Arterial compliance of the common carotid artery was assessed by ultrasound speckle-tracking before and after TAVR. For sub-analysis the study cohort was divided according to aortic valve area <.75 cm<sup>2</sup> (n = 30) vs ≥.75 cm<sup>2</sup> (n = 29). Comparison of pre- and post-procedural strain variables showed an improvement in median radial velocity (<i>P</i> < .0001), radial displacement (<i>P</i> = .007), circumferential strain (<i>P</i> = .004), radial strain rate (<i>P</i> = .023), and circumferential strain rate (<i>P</i> < .0001), while the increase of radial strain showed a trend (<i>P</i> = .082). Analysis of aortic valve area revealed an inverse correlation between aortic valve area and the differences (post-procedural-pre-procedural values) for radial strain rate, and circumferential strain. Moreover, sub-analysis revealed that the increase of carotid strain variables before and after TAVR were more pronounced in the sub-group of aortic valve area .75 vs ≥.75 cm<sup>2</sup>. TAVR led to a reduction of arterial wall stiffness of the common carotid artery assessed by ultrasound speckle-tracking. The decrease of arterial wall stiffness after TAVR was more pronounced in more severe aortic valve stenosis.</p>\",\"PeriodicalId\":8264,\"journal\":{\"name\":\"Angiology\",\"volume\":\" \",\"pages\":\"985-991\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Angiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/00033197231195647\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/8/12 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Angiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/00033197231195647","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/12 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在分析接受经导管主动脉瓣置换术(TAVR)的重度主动脉瓣狭窄患者(59 人)的颈总动脉应变特性。在TAVR前后,通过超声斑点追踪评估了颈总动脉的顺应性。为了进行子分析,研究队列根据主动脉瓣面积2(n = 30)与≥.75平方厘米(n = 29)进行了划分。手术前后应变变量的比较显示,中位桡动脉速度(P < .0001)、桡动脉位移(P = .007)、圆周应变(P = .004)、桡动脉应变率(P = .023)和圆周应变率(P < .0001)均有所改善,而桡动脉应变的增加呈趋势(P = .082)。对主动脉瓣面积的分析表明,主动脉瓣面积与径向应变率和周向应变的差异(手术后-手术前值)呈反向相关。此外,子分析表明,在主动脉瓣面积为.75 vs ≥.75 cm2的亚组中,TAVR前后颈动脉应变变量的增加更为明显。通过超声斑点追踪技术评估,TAVR导致颈总动脉的动脉壁僵硬度降低。主动脉瓣狭窄越严重,TAVR术后动脉壁僵硬度的降低越明显。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Carotid Stiffness After Transcatheter Aortic Valve Replacement.

The present study aimed to analyze common carotid artery strain properties in patients (n = 59) with severe aortic valve stenosis who underwent transcatheter aortic valve replacement (TAVR). Arterial compliance of the common carotid artery was assessed by ultrasound speckle-tracking before and after TAVR. For sub-analysis the study cohort was divided according to aortic valve area <.75 cm2 (n = 30) vs ≥.75 cm2 (n = 29). Comparison of pre- and post-procedural strain variables showed an improvement in median radial velocity (P < .0001), radial displacement (P = .007), circumferential strain (P = .004), radial strain rate (P = .023), and circumferential strain rate (P < .0001), while the increase of radial strain showed a trend (P = .082). Analysis of aortic valve area revealed an inverse correlation between aortic valve area and the differences (post-procedural-pre-procedural values) for radial strain rate, and circumferential strain. Moreover, sub-analysis revealed that the increase of carotid strain variables before and after TAVR were more pronounced in the sub-group of aortic valve area .75 vs ≥.75 cm2. TAVR led to a reduction of arterial wall stiffness of the common carotid artery assessed by ultrasound speckle-tracking. The decrease of arterial wall stiffness after TAVR was more pronounced in more severe aortic valve stenosis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Angiology
Angiology 医学-外周血管病
CiteScore
5.50
自引率
14.30%
发文量
180
审稿时长
6-12 weeks
期刊介绍: A presentation of original, peer-reviewed original articles, review and case reports relative to all phases of all vascular diseases, Angiology (ANG) offers more than a typical cardiology journal. With approximately 1000 pages per year covering diagnostic methods, therapeutic approaches, and clinical and laboratory research, ANG is among the most informative publications in the field of peripheral vascular and cardiovascular diseases. This journal is a member of the Committee on Publication Ethics (COPE). Average time from submission to first decision: 13 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信